请问UL1230是不是与1015一样的? - 无图版
xyxiong --- 2011-12-19 13:48:38
1
UL1230是不是与1015一样的导体结构以及绝缘?
哪位知道二者之间的区别?
晨曦1394 --- 2011-12-19 13:50:17
2
是不一樣的!
UNDERWRITERS LABORATORIES | APPLIANCE WIRING MATERIAL |
Subj.758 | Section 1 | Page 1230 | Issued:1960-12-02 |
| Revised:2009-03-28 |
Style 1230 | Insulated Wire. |
Rating | 105 deg C, 600 Vac, Horizontal flame, 60 deg C wet, optional Oil Resistance 60 deg C. |
Conductor | 26 AWG - 9 AWG solid or stranded. |
Insulation | R/C QMTT2 PVC Insulation Compounds for use in Type TW, 30 mils minimum average, 27 mils minimum at any point. |
Standard | Appliance Wiring Material UL 758. |
晨曦1394 --- 2011-12-19 13:50:35
3
UNDERWRITERS LABORATORIES | APPLIANCE WIRING MATERIAL |
Subj.758 | Section 1 | Page 1015 | Issued:1959-05-01 |
| Revised:2008-05-27 |
Style 1015 | Insulated Wire. |
Rating | 80, 90, 105 deg C, 600 Vac, 750 Vdc, Horizontal flame, Oil Resistant 60 deg C or 80 deg C (optional) |
Conductor | 30 AWG - 2000 kcmil Solid or Stranded Round. |
30-9 AWG conductor size | 30 mils min average | 27 mils minimum at any point |
8-7 AWG | 45 avg | 40 min |
6-2 AWG | 60 avg | 54 min |
1-4/0 AWG | 80 avg | 72 min |
250-500 kcmil | 95 avg | 86 min |
550-1000 kcmil | 110 avg | 99 min |
1100-2000 kcmil | 125 avg | 112 min |
Standard | Appliance Wiring Material UL 758. |
Use | Internal Wiring of Appliances; or Internal Wiring of Appliances where exposed to oil at a temperature not exceeding 60 deg. C or 80 deg. C (whichever is applicable). Tags may also indicate the following: 2,500 V peak - for electronic use only. |
hushao --- 2011-12-19 16:35:24
4
xyxiong --- 2011-12-19 16:52:32
5
R/C QMTT2 PVC Insulation Compounds for use in Type TW,这句话是什么意思?
哪位有UL1230的规格么?国内的感觉可信度不是很高。
不少都把UL1230和1015写在一起,让人感觉就像是一样的结构。
晨曦1394 --- 2011-12-20 16:14:33
6
1015的明顯的耐溫等級的多一些呢
p99p09 --- 2012-01-21 20:02:09
7
不一样的,最近很多人都问这问题呀。
-- 结束 --