谁有UL2586、UL2501的style - 无图版
yiqian --- 2011-12-19 09:10:07
1
谁有UL2586、UL2501的style啊,请分享一下吧
晨曦1394 --- 2011-12-19 10:06:56
2
2586見下<div>
Rating | 105 deg C, 600, 1000 Vac, Cable flame. |
Conductor | 40 AWG min solid or stranded. |
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
Assembly | Two or more conductors or groups of conductors laid parallel or twisted forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. May use same or mixed AWG size. |
Covering | (Optional) A 6 mil or heavier PVC. |
major dia of cable under jacket in inches of 0.700 or less | 30 mils min average | 24 mils minimum at any point |
0.701-1.000 dia | 60 avg | 48 min |
1.001-1.501 dia | 80 avg | 64 min |
1.501-2.500 dia | 110 avg | 88 min |
Standard | Appliance Wiring Material UL 758. |
Use | External interconnection or internal wiring. |
</div>
晨曦1394 --- 2011-12-19 10:07:25
3
UNDERWRITERS LABORATORIES | APPLIANCE WIRING MATERIAL |
Subj.758 | Section 2 | Page 2501 | Issued:1970-04-07 |
| Revised:2008-05-27 |
Style 2501 | Jacketed Cable. |
Rating | 105 deg C, 600 Vac, Cable flame. |
Conductor | 40 AWG min, solid or stranded round, tinned or bare copper. |
Insulation | Labeled or complying with Manufacturer's AWM Procedure |
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
Covering | Optional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly. |
major dia in inches of 0.700 or less | 60 mils min average | 48 mils minimum at any point |
0.701-1.500 dia | 80 avg | 64 min |
1.501-2.500 dia | 110 avg | 88 min |
2.501 dia and larger | 140 avg | 112 min |
Standard | Appliance Wiring Material UL 758. |
Use | Internal wiring or external interconnection of electronic equipment. |
fanyarong --- 2011-12-19 12:29:00
4
下次碰到類似的問題,可以直接上UL官網輸入一個E#查詢一下就OK拉。
maohaiya --- 2011-12-19 13:53:04
5
-- 结束 --