| UNDERWRITERS LABORATORIES | APPLIANCE WIRING MATERIAL |
| Subj.758 | Section 2 | Page 2517 | Issued:1970-10-21 |
| Revised:2009-06-23 |
| Rating | 105 deg C, 300 Vac, Cable flame. |
| Insulation | Labeled or complying with Manufacturer's AWM Procedure. |
| Assembly | Consists of two or more singles, twisted pairs or groups of twisted singles twisted together. The singles or groups of singles may be laid parallel forming a flat, oval or round cable. The lay of the conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
| Braid | Optional, provided over Jacket. |
| Dia. of Cable under Jacket@ | Minimum average | Minimum at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| 0.701 - 1.000 inch | 60 mils | 48 mils |
| 1.001 - 1.501 inch | 80 mils | 64 mils |
@ - Major diameter if cable is flat or oval.
| Standard | Appliance Wiring Material UL 758. |