各位大哥!小兄弟有一事相求大家给我指导;65机第三区温度在升温保温过程中很正常,设定温度为92度。一开机温度上升道100度左右,无法下降。并且显示冷却阀一直打开着。即使强行打开冷却阀循环冷却,仍然是温度无法下降。温度设定及显示是触摸屏的,采样和执行是西门子S7-300 SM331(AI8xTC)K型分度号热电偶、 SM322(DO32x24VDC)24VDC通用小型继电器接通220V冷却电磁阀线圈电源。希望能得到大哥指点。
qiuyiren --- 2011-08-18 11:43:03
2
<DIV class=xxxxContent id=deds2 style="OVERFLOW: auto; WIDTH: 100%"><DIV class=xxxxAd><IFRAME id=google_ads_frame3 name=google_ads_frame3 marginWidth=0 marginHeight=0 src="http://googleads.g.doubleclick.net/pagead/ads?client=ca-pub-5245470700607411&output=html&h=200&slotname=8810507802&w=200&lmt=1313638873&ea=0&flash=10.2.152.26&url=http%3A%2F%2Fwww.dxdlw.com%2FShowPost.asp%3FThreadID%3D90257&dt=1313638873843&shv=r20110810&jsv=r20110719&saldr=1&prev_slotnames=9908240416%2C3492416009&correlator=1313638873718&frm=4&adk=1773478168&ga_vid=237481414.1313638874&ga_sid=1313638874&ga_hid=1315009583&ga_fc=0&u_tz=480&u_his=0&u_java=1&u_h=768&u_w=1366&u_ah=738&u_aw=1366&u_cd=32&u_nplug=0&u_nmime=0&dff=%E5%AE%8B%E4%BD%93&dfs=14&biw=567&bih=428&ref=http%3A%2F%2Fwww.dxdlw.com%2FShowForum.asp%3FForumID%3D29&fu=0&ifi=3&dtd=32" frameBorder=0 width=200 scrolling=no height=200 allowTransparency></IFRAME></DIV>将电热偶拔出,用冷水散在热电偶测量区,看温度有无变化,无变化大概就是热电偶不好换根</DIV> |
<DIV class=loe><SCRIPT>vs("images/face/Default.gif","","qiuyiren","3","37","",".2","0","3","14","","male","2011-5-26 16:40:35","2011-8-18 11:36:10")</SCRIPT><DIV class=bgf>qiuyiren</DIV><DIV class=ofcx onmouseover="this.className='ofc'" onmouseout="this.className='ofcx'">
|
|
<DIV class=loe><SCRIPT>vs("images/face/Default.gif","","qiuyiren","3","37","",".2","0","3","14","","male","2011-5-26 16:40:35","2011-8-18 11:36:10")</SCRIPT><DIV class=bgf>qiuyiren</DIV><DIV class=ofcx onmouseover="this.className='ofc'" onmouseout="this.className='ofcx'">
|
|
<DIV class=loe><SCRIPT>vs("images/face/Default.gif","","qiuyiren","3","37","",".2","0","3","14","","male","2011-5-26 16:40:35","2011-8-18 11:36:10")</SCRIPT><DIV class=bgf>qiuyiren</DIV><DIV class=ofcx onmouseover="this.className='ofc'" onmouseout="this.className='ofcx'">
|
|
<DIV class=loe><SCRIPT>vs("images/face/Default.gif","","qiuyiren","3","37","",".2","0","3","14","","male","2011-5-26 16:40:35","2011-8-18 11:36:10")</SCRIPT><DIV class=bgf>qiuyiren</DIV><DIV class=ofcx onmouseover="this.className='ofc'" onmouseout="this.className='ofcx'">
|
|
线线缆缆 --- 2011-08-18 13:42:10
3
正常现象,以为主机运转产生热量,加上最近天气本身就很热。光靠冷却风扇是不行的 。
要想更好的减温效果,可以采用水冷却炮筒,这样更快,或者安装更好的风冷却系统。
winter321 --- 2011-08-18 14:25:18
4
查看冷却系统是否正常及有效
qiuyiren --- 2011-08-19 15:51:13
5
谢谢你们!winter321、线线缆缆。水冷却系统没有问题,在65机转速下降时,温度下降很快。在20分钟时间内,100度左右降至50度左右。然后温度才开始慢慢上升。
另外我个人认为冷却铜管和机堂外面接触面有无关系?
taoyuan --- 2011-08-19 15:56:54
6
如果是水冷的话,建议看看阀芯是否能够自由关闭
qiuyiren --- 2011-08-22 10:01:12
7
taoyuan 谢谢你!我检测冷却电磁阀水流量、压力、阀芯关闭很正常。
winter321 --- 2011-08-24 12:23:48
8
检查一下蜂巢板及滤网是否过密?
JSCZDXY --- 2011-10-10 16:04:57
9
看看热电偶接触是否良好;冷却水是否通畅。
1987111348 --- 2014-02-11 16:27:35
10
找维修的把