电线电缆网 > 国外线缆 > UL 3075 标准(完整版)

UL 3075 标准 - 无图版

zpc --- 2011-02-14 14:54:40

1

求助UL3075 标准
chicheng --- 2011-02-15 11:22:29

2

UNDERWRITERS LABORATORIES, INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 3 Page 3075 Issued: May 1, 1959
Revised: Oct. 26, 2000
Style 3075 Silicone Rubber-Insulated Wire.
______________________________________________________________________________
Rating 200°C, 600 Volts
______________________________________________________________________________
Conductor No. 10 AWG Solid or Stranded of Nickel or Copper. All
Copper shall be Tin, Nickel or silver Coated. If tinned
Copper strands are used they shall be No. 26 AWG or
* larger.
______________________________________________________________________________
Insulation Nominal 3/64 inch wall silicone rubber, Class 22
______________________________________________________________________________
Covering Same as for Type SF-2 Fixture Wire.
______________________________________________________________________________
*Standard Appliance Wiring Material UL 758.
______________________________________________________________________________
Instructions Same as for Type SF-2 Fixture Wire but omit Insulationto
UL Resistance Test, and Vertical Flame Test
*Representative Spark Test
* Flame Test
______________________________________________________________________________
UL (4) Same as for Type SF-2 Fixture Wire; aging shall be
Counter-Check conducted annually.
Program
______________________________________________________________________________
*Marking General.
______________________________________________________________________________
Use Internal wiring of electric clothes, dryers where exposed
to temperatures not exceeding 200°C or Internal wiring of
appliances where exposed to temperatures not exceeding
200°C.
-- 结束 --