电线电缆网 > 标准求助 > 求助UL2468标准(完整版)

求助UL2468标准 - 无图版

zpc --- 2011-02-14 13:49:04

1

求助UL2468
李小龍 --- 2011-02-14 13:51:51

2

這個求助什麽問題呢?
zpc --- 2011-02-14 14:55:25

3

UL2468标准
pwenhuan --- 2011-02-14 15:09:11

4

UL758 1581啊
yuzeliang --- 2011-02-14 17:19:07

5

救助什么问题也没有写清楚,别人怎么帮你呢

 

chicheng --- 2011-02-15 11:24:34

6

UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subject 758 Section 2 Page 2468 Issued: May 7, 1968
Revised: Jan. 8, 2001
Style 2468 Flat Ribbon-Type Cable.
______________________________________________________________________________
Rating 80°C, 300 Volts.
______________________________________________________________________________
Conductor 2-150, Nos. 32-16 AWG. Tinned or bare, solid or stranded
* copper, conductors laid parallel and in one plane. Same
or Mixed AWG.
______________________________________________________________________________
Insulation Each conductor has a nominal 1/64 in. wall or heavier
thermoplastic (PVC). This forms a flat cable with a single
row of conductors having a 1/2 in. maximum width web between
insulated conductors. The nominal and minimum insulation
thickness along the ripped edges for each conductor shall be
15 and 13 mils, respectively.
______________________________________________________________________________
*Shield Optional.
______________________________________________________________________________
Covering (Optional) PVC. 5 mils min. at any point 80 mils max.
______________________________________________________________________________
*Standard Appliance Wiring Material UL 758.
______________________________________________________________________________
Instructions Detailed Examination.
to UL Tensile Strength and Elongation of Insulation, same as
*Representative for Class 43.
______________________________________________________________________________
UL (4) Detailed Examination.
*Counter-Check (4) Tensile Strength and Elongation of Insulation.
Program (4) Heat Shock on insulated individuals after separation.
*
(4) Cold Bend on insulated individuals after separation.
*
* (4) Horizontal Flame Test on finished cable.
(4) Deformation on insulated individuals after separation.
*
______________________________________________________________________________
*Marking General.
______________________________________________________________________________
Use Internal wiring of Appliances; or internal wiring of
Appliances where exposed to oil at a temperature not
exceeding 60°C or 80°C, whichever is applicable.
-- 结束 --