各位大虾
请问 UL 1007 的印字标准是什么????
[xie 在 2010-1-14 17:15:06 编辑过]
兄 AWM 1007 E****** VW-1 80°C 300V 22AWG XXX c兄 AWM I A 1007 FT1 90°C 300V 22AWG -LF-
这样对不???
我是新手 望前辈指教
[guowilliam 在 2010-1-11 11:07:03 编辑过]
印字中又有80度,又有90度,是不对的。
把后面那一个1007也去掉吧
| UNDERWRITERS LABORATORIES | APPLIANCE WIRING MATERIAL | ||||
| Subj.758 | Section 1 | Page 1007 | Issued:1959-05-01 |
| Revised:2008-05-27 | |||
| Style 1007 | Insulated Wire. | |
| Rating | 80 deg C, 300 Vac, Horizontal flame, Oil Resistant 60 deg C or 80 deg C (optional). |
| Conductor | 32 AWG - 16 AWG Solid or Stranded. |
| Insulation | PVC, 15 mils minimum average, 13 mils minimum at any point. |
| Standard | Appliance Wiring Material UL 758. |
| Marking | General. |
| Use | Internal wiring of appliances; or where exposed to oil at a temperature not exceeding 60 deg C or 80 deg C, whichever is applicable. Tags may indicate the following: 600 V Peak - For Electronic Use Only. |
E****** 兄 AWM 1007 80°C 300V 22AWG VW-1 c兄 AWM I A 1007 80°C 300V FT1 -LF-
谢谢各位的解答

UL758类印字实例:
E****** 兄(UL758认证档案号)AWM(电器布线布缆,符合UL758标准) 20276(UL758 Style Page) 80℃(额定温度) 30V(额定电压) VW-1((UL部分阻燃等级)垂直燃烧)…… c兄(cUL标志,美加联合认证中的加拿大标识)AWM I/II(I:内部布线;II:外部布线,F:用于进一步加工 S:特种用途布线 (具体见UL758 Style Page)) A/B (A:未评估,正常搬运,一般作机内用线 B:进行正常搬运评估,一般是外部用线,C:附加用途,见标牌标志(具体见UL758 Style Page))80℃ 30V FT1(加拿大(CUL部分阻燃等级)垂直燃烧) ******(公司的公司标志)–F-(JQA F-MARK认证标志)
E****** 兄(UL758认证档案号)AWM(电器布线布缆,符合UL758标准) 20276(UL758 Style Page)
三者和型号4个必须严格靠近中间不可以有其它内容
这样能明白否!!!!!!!!已经非常详细了!~

有没有其他国家的如此的印字解释啊????????、、、、