请问各位三并RCA线能否印UL 2468?
UL 2468要求为扁平带状,内层加个屏蔽不知道行不?
TKS!
不行,印2562可以~!
确定不行吗? 一点说法都没有吗?
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 2 Page 2468 Issued: 1968-05-07
Style 2468 Flat Ribbon-Type Cable.
______________________________________________________________________________
Rating 80°C, 300 Volts.
______________________________________________________________________________
Conductor 2-150, Nos. 32-16 AWG. Tinned or bare, solid or stranded
copper, conductors laid parallel and in one plane. Same
or mixed AWG.
______________________________________________________________________________
*Insulation Each conductor has a nominal 15 mils wall or heavier
thermoplastic (PVC). This forms a flat cable with a
single row of conductors having a 1/2 in. maximum width
web between insulated conductors. The nominal and minimum
insulation thickness along the ripped edges for each
conductor shall be 15 and 13 mils, respectively.
______________________________________________________________________________
Shield Optional.
______________________________________________________________________________
Covering (Optional) PVC, 5 mils min. at any point 80 mils max.
______________________________________________________________________________
Standard Appliance Wiring Material UL 758.
______________________________________________________________________________
Instructions Detailed Examination.
*to UL Tensile Strength and Elongation of Insulation.
*Representative Spark Test.
______________________________________________________________________________
UL (4) Detailed Examination.
*Counter-Check (4) Tensile Strength and Elongation of Insulation.
Program (4) Heat Shock.
(4) Cold Bend.
(4) Deformation.
(12) Horizontal Flame Test.
______________________________________________________________________________
Marking General.
______________________________________________________________________________
Use Internal wiring of Appliances; or internal wiring of
Appliances where exposed to oil at a temperature not
exceeding 60°C or 80°C, whichever is applicable.
看下标准吧。。
是一定不行,认真看型号页吧!
学习
绝对不行!!
首先第一层绝缘要求是整体型押出,所以直接排除了你这个非整体型的3芯线还单独屏蔽的结构了!!
也不像楼上说的不能做隔离屏蔽,可以做;
带了屏蔽 就不行了
可以加屏蔽,也可以不加,不强求。
不过要看看你们的认证上有没有特别的说明,如果上面特别说明你们公司不能生产带屏蔽的UL2468的线,那么就不可以。