电线电缆网 > 国外线缆 > UL 2919可否不印VW-1?(完整版)
UL 2919可否不印VW-1? - 无图版
jakezheng --- 2009-05-08 16:55:06
1
请问我司UL认证时,样品的VW-1测试均不通过,那是不是代表我的线材都不能印VW-1?
但我看了"AWM Style pages",上面我看2919.。。。等style 均有要求印VW-1。
UL
Counter-Check
*Program
*
*
*
(4) Detailed Examination.
(4) Tensile Strength and Elongation of Jacket.
(4) Heat Shock on Jacket.
(4) Deformation on Jacket.
(4) Cold Bend on Complete Cable.
(4) Vertical Flame Test on Complete Cable.
不知道可否真的不用印VW-1?
jakezheng --- 2009-05-08 16:57:11
2
chicheng --- 2009-05-08 17:51:19
3
样品送UL测试时,其中任何一项没有通过都不能申请到UL证书,而不是能不能印“VW-1”的问题。
jakezheng --- 2009-05-09 08:53:25
4
chicheng:样品送UL测试时,其中任何一项没有通过都不能申请到UL证书,而不是能不能印“VW-1”的问题。
不会吧! 那为什么UL通知我要来我司做IPI呢?
jakezheng --- 2009-05-09 08:57:13
5
wuyuanbing --- 2009-05-09 13:07:16
6
zxyu --- 2009-06-02 14:26:20
7
qcxmen --- 2009-06-03 14:37:05
8
zym2009 --- 2009-10-30 15:55:52
9
样品送UL测试时,其中任何一项没有通过都不能申请到UL证书,而不是能不能印“VW-1”的问题。
zhengliang --- 2009-10-30 19:26:11
10
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 2 Page 2919 Issued: 1978-03-22
Revised: 2005-04-18
Style 2919 | Low Voltage Computer Cable. | |
Rating | 80°C, 30 Volts. | |
Insulated Conductors | No. 40 AWG minimum. Labeled or complying with Manufacturer’s AWM Procedure having a minimum rating of 80°C, 30 V. | |
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. | |
Covering | (Optional) - A 6 mil or heavier PVC covering may be extruded over the conductor assembly. | |
Shield | Optional. | |
Jacket | PVC - Class 43 THICKNESS (MILS) #Dia of cable under jacket Minimum Minimum in inches Average at any point 0.425 or less 30 24 0.426 - 0.700 45 36 0.701 - 1.000 60 48 1.000 - 1.500 80 64 1.501 - 2.500 110 88 2.501 and larger 140 112 # - Major dia if cable is flat or oval. | |
Braid | Optional. | |
Standard | Appliance Wiring Material UL 758. |
(Continued on Page 2919A)
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 2 Page 2919A Issued: 1978-03-22
Revised: 2003-02-17
Instructions to UL Representative | Detailed Examination. Tensile Strength and Elongation of Jacket. The designation of all Styles of the individual conductors used making up the cable assembly shall be available, and the UL Representative’s tag shall indicate if the Style is labeled or not. If they are not labeled, the appropriate Follow-Up Tests shall be conducted. | |
UL Counter-Check Program * | (4) Detailed Examination. (4) Tensile Strength and Elongation of Jacket. (4) Heat Shock on Jacket. (4) Deformation on Jacket. (4) Cold Bend on Completed Cable. (12) Cable Flame Test on Completed Cable. If the insulated Styles are not labeled, the appropriate Follow-Up Tests shall be conducted. | |
Marking | General. | |
Use | As internal wiring or external interconnection in Class 2 Circuits of electronic computers and electric business machines. |