UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 2 Page 20251 Issued: 1983-02-23
Revised: 2003-08-07
Style 20251 Multi-Conductor Cord.
______________________________________________________________________________
Rating 60°C, 150 Volts, 300 Volts peak.
______________________________________________________________________________
Conductor Two to ten 18-33 AWG, tinned or bare, solid, stranded,
or tinsel. May include mixed AWG sizes.
______________________________________________________________________________
Insulation Polypropylene, 7 mils minimum average, 5 mils minimum
at any point.
______________________________________________________________________________
Shielding (Optional) One or more may be shielded.
______________________________________________________________________________
Jacket PVC, Class 43, 20 mils minimum average, 16 mils minimum
at any point.
______________________________________________________________________________
Assembly Cable may be either straight or wound in retractile
form. Core may be either flat or round. Barrier
layer and/or fillers optional.
______________________________________________________________________________
Standard Appliance Wiring Material UL 758.
______________________________________________________________________________
Instructions Detailed Examination.
to UL Physical Properties, Unaged Insulation and Jacket.
Representative Spark Test.
Flexibility Test, unaged, if unable to perform Physical
Properties on tinsel and/or stranded conductors.
______________________________________________________________________________
UL (4) Detailed Examination.
Counter-Check (4) Physical Properties of Insulation and Jacket,
Program Unaged and Aged.
(4) Heat Shock.
(4) Cold Bend.
(4) Deformation.
* (12) Horizontal Flame Test on Cable.
(4) Flexibility Test, if unable to perform Physical
Properties on Tinsel and/or Stranded Conductors.
______________________________________________________________________________
Marking General.
______________________________________________________________________________
Use Internal cable of electronic equipment, or as
"Handset Wire or Telephone Cord for Subscriber Sets".