电线电缆网 > 通讯电缆 > 美国客户的要求过分吗(完整版)
美国客户的要求过分吗 - 无图版
jswjyzw --- 2008-10-30 20:48:39
1
弟兄门,帮我看看衰减指标能实现吗?指标该定多少?
RG59
CONDUCTOR:
AWG 20
Stranding: Solid
Conductor Diameter: .032 in.
Conductor Material: BCCS - Bare Copper Covered Steel
INSULATION:
Insulation Material: Gas-injected FPE - Foam Polyethylene
Insulation Diameter: .144 in.
Bonded Aluminum Foil-Polyester Tape-AluminumFoil 100%
Braid
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter: .237 in.
MECHANICAL CHARACTERISTICS:
Operating
Max. Recommended Pulling Tension: 80 lbs.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification CATV, CM
CEC/C(UL) Specification CM
ELECTRICAL CHARACTERISTICS:
Nom. Characteristic Impedance 75 +/- 3 Ohms
Nom. Inductance .097 µH/ft
Nom. Capacitance Conductor to Shield 16.2 pF/ft
Nominal Velocity of Propagation 83 %
Nominal Delay 1.2 ns/ft
Nom. Conductor DC Resistance @ 20 Deg. C 44.5 Ohms/1000 ft
Nominal Outer
Nom. Attenuation :
Description Frequency (MHz) Nom. Attenuation (dB/100 ft.)
5 0.8
55 1.8
211 3.4
500 5.2
750 6.5
862 7.0
1000 7.7
1450 9.3
1800 10.3
2250 11.9
cuijiude --- 2008-10-30 21:37:12
2
[cuijiude 在 2008-10-30 21:38:15 编辑过]
jswjyzw --- 2008-10-31 09:05:30
3
楼上的大虾,指点一下吧.
谢谢
wjf5301107 --- 2008-10-31 09:59:17
4
楼主你确认它的单位为100ft?
特缆先锋 --- 2008-10-31 13:01:44
5
zhyx2006 --- 2008-10-31 13:20:32
6
5MHZ 小于3.9/100m,1000MHZ 小于27/100M保守
kaka2004 --- 2008-10-31 13:42:16
7
還要看BCCS的電導率是多少了?
zhyx2006 --- 2008-10-31 15:03:12
8
kaka2004:它上面已经给出内导体电阻,导电率23%還要看BCCS的電導率是多少了?
AbelGuo --- 2008-10-31 15:31:46
9
客户要求永远都是苛刻的,,没有什么过分。因为他就是你的上帝。。。
能不能做到就看你家的能力。既然有这样的要求肯定是可以做到的。我想他们是从BELDEN网上复制的。
老文 --- 2008-10-31 17:02:17
10
zajabcyx --- 2008-10-31 18:29:26
11
有点难,但总会有办法的
jswjyzw --- 2008-11-01 09:16:31
12
jswjyzw --- 2008-11-03 19:15:45
13
单位没有错!
感谢各位指点,受教了.
我考虑导电率为26%(放宽10%).
请教5楼的兄弟,发泡材料的选择上有何讲究?
jswjyzw --- 2008-11-03 19:18:33
14
我理论计算的衰减怎么也不可能满足指标,不知道怎么回事?
我按照射频电缆设计规范计算的,哪为仁兄帮我指导其中的问题.
jswjyzw --- 2008-11-03 19:20:25
15
请教2楼,可以做到12。5吗?怎么做?