请问UL2464  22AWG*8C   外被OD最小能做到多少?

whf764 --- 2008-08-01 16:38:24

2

这个看ul2464的规范就可以.

Jacket      PVC - Class 43

 

                         THICKNESS OF PVC JACKET (mils)

 

            #Dia. of Cable                  Minimum

            Under Jacket        Minimum     at any

              in Inches         Average      point  

 

            0.700 or less          30             24

            0.701 - 1.000          45             36

            1.001 - 1.500          60             48

            1.501 - 2.500          80             64

            2.501 - 4.000         110             88

            4.001 or larger        140           112


bsdtdw --- 2008-08-01 16:57:17

3

6.0MM线径

ouyang --- 2008-08-03 12:46:53

4

过粉线5.7就可以了
810707 --- 2008-08-04 10:07:15

5

没有死的,只要符合规范,综合考量再定!

AbelGuo --- 2008-08-04 22:29:36

6

是的要综合考量.要看你们内部芯线的厚度再根据整体OD来设计厚度.

xiaofan --- 2008-08-05 09:12:53

7

依照UL標準進行即可.也不是隨便由自已定的
xibienihao --- 2008-08-05 13:44:42

8

请问各位有否UL2464的资料,能否传给我:xibienihao@163.com

谢谢

wei --- 2008-08-05 14:59:59

9

5.5mm没问题

麦子红了 --- 2008-08-05 18:08:40

10

下面是UL2464对线径与厚度的对应关系,希望对楼主能有所帮助!

完成外径 MM                   最小平均厚度MM      任意点最小厚度

17.78or less
17.78-25.4
25.4-38.1
38.1-63.5
63.5-101.6
101.6or larger
0.76mm
1.143
1.524
2.03
2.794
3.56
0.6
0.914
1.219
1.626
2.235
2.845
xibienihao --- 2008-08-06 11:24:17

11

上面楼主请问有没有芯线大小方面的资料
麦子红了 --- 2008-08-06 12:31:07

12

芯线OD要根据你交合外径来确定,只有2464的安规!要的话,可以传给你!!

xibienihao --- 2008-08-12 10:39:56

13

好啊,请传给我.谢谢!

另外请问有没有UL2725  UL2517的安规? 有的话也请一并转发.谢谢

xibienihao@163.com

yyx512 --- 2008-08-16 11:25:10

14

在规范范围内就可以了