xibienihao --- 2008-08-01 16:04:24
1
请问UL2464 22AWG*8C 外被OD最小能做到多少?
whf764 --- 2008-08-01 16:38:24
2
Jacket PVC - Class 43
THICKNESS OF PVC JACKET (mils)
#Dia. of Cable Minimum
Under Jacket Minimum at any
in Inches Average point
0.700 or less 30 24
0.701 - 1.000 45 36
1.001 - 1.500 60 48
1.501 - 2.500 80 64
2.501 - 4.000 110 88
4.001 or larger 140 112
bsdtdw --- 2008-08-01 16:57:17
3
6.0MM线径
ouyang --- 2008-08-03 12:46:53
4
810707 --- 2008-08-04 10:07:15
5
没有死的,只要符合规范,综合考量再定!
AbelGuo --- 2008-08-04 22:29:36
6
是的要综合考量.要看你们内部芯线的厚度再根据整体OD来设计厚度.
xiaofan --- 2008-08-05 09:12:53
7
xibienihao --- 2008-08-05 13:44:42
8
请问各位有否UL2464的资料,能否传给我:xibienihao@163.com
谢谢
wei --- 2008-08-05 14:59:59
9
5.5mm没问题
麦子红了 --- 2008-08-05 18:08:40
10
下面是UL2464对线径与厚度的对应关系,希望对楼主能有所帮助!
完成外径 MM 最小平均厚度MM 任意点最小厚度
17.78or less 17.78-25.4 25.4-38.1 38.1-63.5 63.5-101.6 101.6or larger | 0.76mm 1.143 1.524 2.03 2.794 3.56 | 0.6 0.914 1.219 1.626 2.235 2.845 |
xibienihao --- 2008-08-06 11:24:17
11
麦子红了 --- 2008-08-06 12:31:07
12
芯线OD要根据你交合外径来确定,只有2464的安规!要的话,可以传给你!!
xibienihao --- 2008-08-12 10:39:56
13
yyx512 --- 2008-08-16 11:25:10
14
在规范范围内就可以了