电线电缆网 > 新手区 > SAE J1128与SAE J1127对应线材的火花测试电压是多少?(完整版)

SAE J1128与SAE J1127对应线材的火花测试电压是多少? - 无图版

HONEY168WW --- 2023-07-01 08:37:52

1

请问有谁知道SAE J1128与SAE J1127对应线材的火花测试电压是多少?查看了这两个标准,都没有相关内容描述

游客 --- 2023-07-02 10:22:18

2

6.6 Insulation Faults
This is an in-process testintended for mass production of all cable covered in this document. The test electrode shall be of the link or bead-chain type and shall make intimate contact with the cable surface under test. The speed of the cable and the length of the electrode field shall ensure that each point of the cable is loaded with at least nine complete voltage cycles.
The test voltage is 2 kV (AC).
HONEY168WW --- 2023-07-03 11:20:38

3

好的  谢谢
xyh2018 --- 2023-07-04 17:14:28

4

游客:

6.6 Insulation Faults

This is an in-process testintended for mass production of all cable covered in this document. The test electrode shall be of the link or bead-chain type and shall make intimate contact with the cable surface under test. The speed of the cable and the length of the electrode field shall ensure that each point of the cable is loaded with at least nine complete voltage cycles.

The test voltage is 2 kV (AC).

请问下这段是在哪个标准里面的? 谢谢!

IVAN728 --- 2023-07-15 10:55:23

5

SAE J1128-2020版本里面有描述“绝缘缺陷”的测试电压是:AC 2KV
-- 结束 --