电线电缆网 > 国外线缆 > 求UL1007和1015,2464标准(完整版)

求UL1007和1015,2464标准 - 无图版

haotong --- 2008-05-14 19:02:22

1

有那位知道UL的线的标准吗?UL1007和1015,2464、
jackeyli --- 2008-05-15 08:16:18

2

UNDERWRITERS LABORATORIES INC.                APPLIANCE WIRING MATERIAL

Subj. 758      Section 1       Page 1007        Issued:  1959-05-01

                                 Revised:  2002-12-05

 

Style 1007     Polyvinyl Chloride Insulated Wire.

______________________________________________________________________________

 

Rating     80°C, 300 V.

______________________________________________________________________________

 

Conductor      32-16 AWG, solid or stranded.

______________________________________________________________________________

 

Insulation     Polyvinyl Chloride, 15 mils minimum average,

           13 mils minimum at any point, 60 or 80°C in oil,

           if applicable.

______________________________________________________________________________

 

Standard       Appliance Wiring Material UL 758.

______________________________________________________________________________

 

Instructions    Detailed Examination.

to UL          Physical Properties, Unaged.

Representative  Spark Test.

______________________________________________________________________________

 

UL         (4)  Detailed Examination.

Counter-Check   (4)  Physical Properties.

Program        (4)  Heat Shock.

           (4)  Cold Bend

*          (4)  Deformation.

*          (12) Horizontal Flame Test.

______________________________________________________________________________

 

Marking        General.

______________________________________________________________________________

 

Use        Internal wiring of appliances; or where exposed to oil

           at a tempera­ture not exceeding 60°C or 80°C, whichever

           is applicable.  Tags may indicate the following: 

           600 V Peak - For Electronic Use Only.

UNDERWRITERS LABORATORIES INC.                APPLIANCE WIRING MATERIAL

Subj. 758      Section 1       Page 1015        Issued:  1959-05-01

                                 Revised:  2003-02-17

 

Style 1015     PVC Insulated Wire.

______________________________________________________________________________

 

Rating     80°C, 90°C or 105°C; 600 V ac, 750 V dc.

______________________________________________________________________________

 

Conductor      30 AWG - 2000 kcmil.

______________________________________________________________________________

 

Insulation     PVC

 

                           Min. Avg.     Min at Any Point

              Size              Mils            Mils       

 

              30-9              30         27

               8,7           45         40

               6-2           60         54

              1-4/0             80         72

              250-500 kcmil         95         86

              550-1000 kcmil        110           99

              1100-2000 kcmil      125          112

_____________________________________________________________________________

 

Standard       Appliance Wiring Material UL 758.

_____________________________________________________________________________

 

Instructions    Detailed Examination.

to UL          Physical Properties, unaged, Class 43.

Representative  Spark Test.

_____________________________________________________________________________

 

UL         (4)  Detailed Examination.

Counter-Check   (4)  Physical Properties, Class 43.

Program        (4)  Heat Shock.

           (4)  Cold Bend.

            (4)  Deformation.

*          (12) Horizontal Flame Test.

_____________________________________________________________________________

 

Marking        General.

_____________________________________________________________________________

 

Use        Internal Wiring of Appliances; or Internal Wiring of

Appliances where exposed to oil at a temperature not exceeding 60 deg. C or 80 deg. C (whichever is applicable).  Tags may also indicate the following: 2,500 V peak - for electronic use only.

UNDERWRITERS LABORATORIES INC.                APPLIANCE WIRING MATERIAL

Subj. 758      Section 2       Page 2464        Issued:  1968-05-02

                                 Revised:  2003-05-02

 

Style 2464     PVC Jacketed Cable.

______________________________________________________________________________

 

Rating     80°C, 300 V.

______________________________________________________________________________

 

Insulated      Labeled or complying with manufacturer's AWM Procedure

Conductors     having a minimum rating of 80°C and 300 V.

______________________________________________________________________________

 

Assembly       Two or more singles, twisted pairs of groups of twisted

           singles twisted together or singles or groups of singles

           may be laid parallel to form flat, oval or round cable. 

           Lay not specified.  Barrier layer and/or fillers optional.  

           Manufacturer shall maintain a complete description of each

           assembly.  May use same or mixed AWG size.

______________________________________________________________________________

 

*Covering      (Optional.)

______________________________________________________________________________

 

Shield     Optional.

______________________________________________________________________________

 

Jacket     PVC - Class 43

 

                        THICKNESS OF PVC JACKET (mils)

 

           #Dia. of Cable                 Minimum

           Under Jacket     Minimum       at any

              in Inches           Average         point  

 

           0.700 or less          30           24

           0.701 - 1.000         45           36

           1.001 - 1.500         60           48

           1.501 - 2.500         80           64

           2.501 - 4.000        110          88

           4.001 or larger       140        112

 

           # Major diameter if cable is flat or oval.

______________________________________________________________________________

 

Braid          Optional.

______________________________________________________________________________

 

Standard       Appliance Wiring Material UL 758.

______________________________________________________________________________

                              (Continued on Page 2464A)


 

UNDERWRITERS LABORATORIES INC.               APPLIANCE WIRING MATERIAL

Subj. 758      Section 2       Page 2464A     Issued:  1968-05-02

                                Revised:  2003-05-02

 

Instructions    Detailed Examination of the cable assembly and jacket.

to UL          Physical Properties of Jacket.

Representative    Dielectric Strength Test, 1500 Volts (shielded cable only).

 

The designation of all Styles of the individual conductors used making up the cable assembly shall be available, and the UL Representative’s tag shall indicate if the Style is labeled or not.  If they are not labeled, the appropriate Follow-Up Tests shall be conducted.

______________________________________________________________________________

 

UL         (4)  Detailed Examination.

Counter-Check   (4)  Physical Properties of Jacket.

Program        (4)  Heat Shock on Jacket.

           (4)  Cold Bend on Completed Cable.

           (4)  Deformation on Jacket, Class 43.

           (12) Cable Flame Test on Completed Cable.

 

If the insulated styles are not labeled, the appropriate Follow-Up Tests shall be conducted.

______________________________________________________________________________

 

Marking        General.

______________________________________________________________________________

 

Use        Internal wiring or external interconnection of electronic

           equipment (such as desk-type calculators, dictating

           machines, or x-ray equipment).

kaitai --- 2008-05-17 02:44:25

3

谢谢!

6886522 --- 2008-05-18 12:17:16

4

怎么是英文 我看不懂  可以弄个中文版的吗 ?  谢了
-- 结束 --