电线电缆网 > 产品认证 > 请求FFC线20624 20798的标准(完整版)

请求FFC线20624 20798的标准 - 无图版

jiro --- 2008-05-12 10:21:49

1

请斑竹提供一下 FFC线20624 20798的标准和定义给我

我一直想学习  但网上一点资料找不到

谢谢!

cuijiude --- 2008-05-12 12:44:56

2

UNDERWRITERS LABORATORIES INC.               APPLIANCE WIRING MATERIAL

Subj. 758       Section 2       Page 20624       Issued:   1989-09-20

                                    Revised:   2003-11-14

 

Style 20624     Insulated Flat Cable.

 _____________________

 

Rating      80°C, 60 Volts.

___________________________

 

Conductor       2-150, material not specified.  40-12 AWG flat or round

            conductors.  Straight or irregular parallel in one plane.

            Flat conductors 1.0 - 10.0 mils thick, 10-100 mils wide.

_________________________________________________________

 

*Insulation     (1)  PVC, 3.5 mils minimum bonded each side, or

            (2)  0.8 mil minimum biaxially oriented PETP

                 film bonded each side with 0.5 mil polyester adhesive

                            or

            (3)  0.8 mils minimum PETP film or flame retardant

                 polyester film and 0.5 mil minimum PVC on each side

                 of conductors laminated together.  10 mils minimum

                 edge width and 3 mils minimum between conductors.

            (4)  0.8 mils minimum polyimide film bonded on each side

                 of conductors with 0.4 mil minimum polyester

                 adhesive.  Total combined thickness shall be 1.2 mils

                 minimum.

__________________________________________________________________

 

Shield      (Optional) Metal faced polyester tape.

            Drain wire optional.

______________________________________________________________

 

Standard        Appliance Wiring Material UL 758.

________________________________________________________________

 

Instructions    Detailed Examination.

to UL           Flexing - flatwise into a U-bend around a 1/8 in.

Representative     diameter mandrel.

*           Spark Test.

_____________________________________________________________

 

UL          (4)  Detailed Examination.

Counter-Check   (4)  Flexing - Conditioned 7 days in air oven at 113°C,

Program          then flexed as above.

*           (12) Horizontal Flame Test.

________________________________________________________________

 

Marking     General.

 _____________________________________________

 

Use         Internal wiring of Class 2 circuits in electronic

            equipment.

 

 

 

[cuijiude 在 2008-5-12 12:48:04 编辑过]

cuijiude --- 2008-05-12 12:45:19

3

UNDERWRITERS LABORATORIES INC.               APPLIANCE WIRING MATERIAL

Subj. 758       Section 2       Page 20798       Issued:  1993-06-24

                                    Revised:  2003-06-20

 

Style 20798     Insulated Flat Cable.

______________________________________________________________________________

 

Rating      80°C, 60 V.

______________________________________________________________________________

 

Conductor       2-150, copper foil.  Straight parallel in one plane. 

            Conductors 1.0 - 10.0 mils thick, 10-100 mils wide.

______________________________________________________________________________

 

Insulation      0.4 mil minimum biaxially oriented PETP (polyester)

film bonded each side with 0.5 mil polyester adhesive.  Minimum 13 mils of insulation between the outside edges and the first conductor and 7 mils minimum width between adjacent conductors.

______________________________________________________________________________

 

Shield      (Optional) Metal faced polyester tape.  Drain wire optional.

______________________________________________________________________________

 

Covering        (Optional) Polyester (Mylar) film, 0.02 - 4.0 mils

            bonded to cable with polyester adhesive.

______________________________________________________________________________

 

Standard        Appliance Wiring Material UL 758.

______________________________________________________________________________

 

Instructions    Detailed Examination.

*to UL      Flexibility, Unaged.

Representative  Spark Test.

______________________________________________________________________________

 

UL          (4)  Detailed Examination.

*Counter-Check  (4)  Flexibility

Program     (12) Horizontal Flame Test.

______________________________________________________________________________

 

Marking     General.

______________________________________________________________________________

 

Use         Internal wiring of Class 2 circuits in electronic

            equipment.

 

jiro --- 2008-05-12 14:58:36

4

谢谢啦!!请问斑竹 

FFC线您还有其它资料吗?贴出来可以吗

感谢了

-- 结束 --