电线电缆网 > 国外线缆 > 哪位有UL21283 的标准资料?(完整版)
哪位有UL21283 的标准资料? - 无图版
xxw123 --- 2018-01-05 11:17:46
1
哪位大神有UL21283 的标准资料?请求共享一下
chicheng --- 2018-01-05 20:15:08
2
APPLIANCE WIRING MATERIAL |
Subj.758 | Section 2 | Page 21283 | Issued:2003-09-05 |
Revised:2011-09-07 |
Style 21283 | Multiconductor Cable with Extruded non-integral jacket |
Rating | 80 deg C, 30 Vac, Horizontal flame. | |||||||||
Conductor | 40 AWG min. solid or stranded round, tinned or bare copper. | |||||||||
Insulation | Labeled or complying with manufacturer's AWM Procedure. | |||||||||
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturers shall maintain a complete description of each assembly. May use same or mixed AWG size. | |||||||||
Shield | Optional. Over one or more of the insulated conductors or between the conductor assembly and the optional covering. | |||||||||
Covering | Optional. Extruded FRPE or extruded PVC covering over the conductor assembly, 5 mils minimum thickness at any point. | |||||||||
Jacket | Extruded FRPE, 12 mils min average thickness, 10 mils minimum thickness at any point. | |||||||||
Standard | Appliance Wiring Material UL 758. | |||||||||
Marking | General. | |||||||||
Use | Internal wiring of electrical equipment. | |||||||||
UL and the UL Logo are trademarks of UL LLC © 2018
xxw123 --- 2018-01-15 11:11:18
3
谢谢<div>
</div>
</div>