电线电缆网 > 特种电缆 > UL 1354 铁氟龙电线請教(完整版)

UL 1354 铁氟龙电线請教 - 无图版

Elva --- 2007-06-20 11:53:11

1

請教各位以下詳細資料,多謝!

铁氟龙  UL1354  36# 

铁氟龙  UL1354  40#

铁氟龙  UL1354  RF

[Elva 在 2007-6-20 13:36:20 编辑过]

skywish --- 2007-06-20 12:04:13

2

   也不知道你想要知道什么!铁氟龙线UL1354偶以前是没有做过拉!不过UL1333,1371等等!都做过!参照标准UL758,UL1581及CSA C22.2 NO.210..2可通过UL VW-1 及CSA FT1垂直耐燃测试!具有优良热稳定性和机械耐磨电绝缘性能,可抗强酸强碱,耐腐蚀,耐火不燃,氧指数高,低烟无卤,耐老化,使用标准厚度,易剥,切断容易,额定电压:300V,额定温度:-80度~+150度,绝缘采用FEP聚全氟乙丙烯绝缘!以上资料仅供参考!!
Elva --- 2007-06-20 13:38:27

3

謝謝
skywish
jollyzhong --- 2007-06-23 16:59:22

4

我知道你说的是什么

1354 #40 7/0.03锡铜合金 ,绝缘0.24,27+/-1 0.03镀锡铜,铜箔胶带,pet胶带 od=0.35

1354 #36 7/0.05锡铜合金,绝缘0.27,29+/-1 0.03镀锡铜,铜箔胶带,pet胶带 od=0.39

1354rf就要看你的规格了!

jollyzhong --- 2007-06-23 17:15:19

5

UNDERWRITERS LABORATORIES INC.           APPLIANCE WIRING MATERIAL

Subject 758   Section 1   Page 1354 Issued: Feb. 19, 1964

                                    Revised: Aug. 18, 1998

 

 

Style 1354

 

Coaxial Cable.

 

 

Rating

 

60°C or 80°C, 30 V.

 

 

 

Conductors

 

No. 44 AWG min, material not specified.

 

 

 

Insulation

 

2 mils min at any point, 125 mils max, Solid or Cellular PE, FRPE, Polypropylene, PFA, FEP, ECTFE, PTFE, ETFE or combination thereof with or without irradiation.  The insulation may be tape wrapped solid or cellular PTFE applied directly over the conductor or applied as a spiral wrapped Polyethylene thread (5 mils min, 40 mils max) and enclosed with “tubed on” insulation.

 

 

 

Covering

 

Optional - Extruded PVC Polyethylene or Irradiated Polyethylene, or PFA, or Polyester film.  Thicknesses not specified.

 

 

 

Shield

 

Page 24, required if outer shield is not provided.

 

 

 

Covering

 

Optional - Extruded PVC, or PFA, or heat sealed PVC tape, Polyamide Polyester, Kynar, FEP or PTFE, ECTFE, Tefzel, or lacquered braids, or tape wrapped PTFE Polyester film or Polyester-Polyethylene laminated film.  Thicknesses not specified.

 

 

 

Outer Shield

 

Page 24, (optional if inner shield is provided).

 

 

 

 

 

*

 

Outer Covering

 

Optional (required if outer shield is provided) - Extruded PVC, or PFA, or heat sealed PVC tape, Polyamide, Polyester, Kynar, FEP, PTFE, ECTFE, Tefzel, irradiated PE, irradiated PVC Polyurethane, or lacquered braid, thicknesses not specified.

 

 

 

Standard

 

UL 1581, Reference Standard for Electrical Wires Cables, and Flexible Cords.

 

(Continued on Page 1354A)
UNDERWRITERS LABORATORIES INC.           APPLIANCE WIRING MATERIAL

Subject 758   Section 1  Page 1354A Issued: Feb. 19, 1964

                                    Revised: April 24, 1992

 

 

 

Instructions

to UL

Representative

 

 

Detailed examination.

 

 

UL Counter-Check Program

 

 

(4) Detailed Examination.

(4) Horizontal Flame Test - Page 31.

 

 

Marking

 

General, Page 13.

 

 

 

Use

 

Internal wiring of Class 2 Circuits of Electronic Equipment or as insulated single in jacketed multiconductor cables.

 

Elva --- 2007-06-29 16:02:06

6

多謝謝

jollyzhong

michael --- 2007-06-29 18:31:25

7

四楼的规格全都正确,与HSD的非常接近。
gfren --- 2007-07-03 22:56:07

8

查UL规格书不就行了?

qwqzhw --- 2010-12-06 16:51:55

9

很简单的东西,参考style page就好了

liwanjun926 --- 2010-12-24 20:32:46

10

楼主不 错!

 

-- 结束 --