[问题求助] 请帮忙 1032 电子线

P:2011-09-01 07:08:54

1

UL  1032 电子线系列的用的什么规格的PVC啊!!!~ 多少度的!有什么特殊的吗?和UL1015用的塑料一样吗?

optical fiber drawing tower - 光纤拉丝塔 (0) 投诉

P:2011-09-20 16:50:32

2

UNDERWRITERS LABORATORIESAPPLIANCE WIRING MATERIAL
Subj.758Section 1Page 1032Issued:1959-05-01
Revised:2008-05-27
Style 1032Insulated Wire.

Rating90 deg C, 1000 Vac, 1200 Vdc, Horizontal flame, Oil Resistant 60 deg C or 80 deg C (optional).
Conductor30 AWG - 2000 kcmil Solid or Stranded Round, tinned or bare copper.
InsulationPVC
30-9 AWG conductor size30 mils min average27 mils minimum at any point
8-7 AWG45 avg40 min
6-2 AWG60 avg54 min
1-4/0 AWG80 avg72 min
250-500 kcmil95 avg86 min
550-1000 kcmil110 avg99 min
1100-2000 kcmil125 avg112 min
ShieldOptional.
CoveringOptional. PVC, 5 mils minimum at any point, 40 mils maximum.
BraidOptional.
JacketOptional. PVC, 30 mils min average, 23 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Appliances; or where exposed to oil at a temperature not exceeding 60 deg. C or 80 deg. C (whichever is applicable). Tags may also indicate the following: 3500 V peak - for electronic use only.

derivation - 衍生物,引水道,分支;分路,分流 (0) 投诉

P:2011-09-20 16:53:35

3

标准上面规定90℃

polyethylene crystallinity - 聚乙烯结晶性,聚乙烯结晶度 (0) 投诉

P:2011-09-24 14:25:55

4

PVC可以是90℃(额定电压Vac:1000V、Vdc:1200V)、60℃、80℃

PVC compound supplying system - 聚氯乙烯混合物供给系统 (0) 投诉

P:2011-09-25 13:22:38

5

asbestos-resin tape - 石棉-树脂复合带 (0) 投诉

P:2011-10-11 13:52:01

6

官網上可以看.

 