首页 > 通讯电缆

[同轴电缆] 有谁知道如下几款RG系列同轴线的具体规格?

P:2007-04-12 14:28:34

1

有谁知道如下几款RG系列同轴线的具体规格?

RG-223/U

RG-214/U

RG-142B/U

RG-11/U

RG-7U

gaseous insulating material - 气体绝缘材料 (0) 投诉

P:2007-04-12 23:18:29

2

天, binhao2005发的都是什么呀?

fully-connectorized optical cable - 全接头化光缆 (0) 投诉

P:2007-05-05 21:00:30

3

RG-11/U

1.63CCS+7.11FPE+0.052自粘铝箔+16*6*0.16+10.03PVC

terminal connector - 终端线夹 (0) 投诉

P:2007-05-05 21:13:32

4

RG -7U

1.29CCS+5.7Foam PE+0.052自粘铝箔+16*5*0.16AL+8.0PVC

printed wiring - 印刷电路,印刷布线 (0) 投诉

P:2007-07-28 20:20:37

5

RG223

SC0.9mm+SPE2.9mm+SC0.12mm*7*16(L=16.8mm)+SC0.12mm*7*16(L=12.3mm)+PVC5.3mm

 

RG214

TC0.724*7mm+SPE7.25mm+TC0.16mm*8*24(L=35mm)+TC0.16mm*8*24(30mm)+PVC10.8mm

cable-forming - 电缆成型,成缆 (0) 投诉

P:2007-07-31 10:06:10

6

Technical parameters of commonly-used coaxial cable

<DIV align=center>

型号 Model

No. of wire/O. D. (mm)

O. D. of insulation (mm)

Al foil

shield n/(mm)

O. D. of jacket (mm)

Characteristic impedance (Ω)

O.D. of steel messenger (mm)

RG59U

0.65
CS / CU

3.7±0.1
PEF / PES

13×0.04

32/48/64/80/96/112/ 128/ 0.12 BC /AL / TC

6.0±0.1

75Ω±5

 

RG59U
messengered

0.65
CS / CU

3.7±0.1
PEF / PES

13×0.04

32/48/64/80/96/112/ 128/ 0.12 BC /AL / TC

6.0±0.1

75Ω±5

1.20 single
1.83 dual

RG59U
Tir-shield

0.65
CS / CU

3.7± 0.1
PEF / PES

13×0.04

32/48/64/80/96/112/ 128/ 0.12 BC /AL / TC

6.2±0.1

75Ω±5

 

RG59U
quad-shield

0.65
CS / CU

3.7±0.1
PEF / PES

13×0.04

32/48/64/80/96/112/ 128/ 0.12 BC /AL / TC

6.73±0.1

75Ω±5

 

RG58U

1/0.8
CU

2.95±0.05
PES

/

32/48/64/80/96/112/ 128/ 0.12 BC /AL / TC

4.95±0.05

50Ω±3

 

RG58C/U

19/0.18
TC

2.95
PES

/

32/48/64/80/96/112/ 128/ 0.12 BC /AL / TC

4.95±0.05

50Ω±3

 

RG6U

1/1.02
CS/CU/AL

4.8±0.10
PEF

17×0.04

32/48/64/80/96/112/ 128/ 0.12 BC /AL / TC

7.0±0.1

75Ω±5

 

RG6U
Five spaces

1/1.02
CS/CU/AL

4.8±0.10
PES

/

32/48/64/80/96/112/ 128/ 0.12 BC /AL / TC

7.0±0.1

75Ω±5

 

RG6U
messengered

1/1.02
CS/CU/AL

4.8±0.10
PEF

17×0.04

32/48/64/80/96/112/ 128/ 0.12 BC /AL / TC

7.0±0.1

75Ω±5

1.20 single
1.83 dual

RG6U
Tir-shield

1/1.02
CS/CU/AL

4.8±0.10
PEF

17×0.04

32/48/64/80/96/112/ 128/ 0.12 BC /AL / TC

7.1±0.1

75Ω±5

 

RG6U

1/1.02
CS/CU/AL

4.8±0.10
PEF

17×0.04<

32/48/64/80/96/112/ 128/ 0.12 BC /AL / TC

7.54±0.1

75Ω±5<

 

RG11U

1/1.63
CS/CU

7.3±0.20
PEF

25×0.04

32/48/64/80/96/112/128/ 0.12 /0.15 BC/AL/TC

10.3±0.20

75Ω±5

 

RG11U
messengered

1/1.63
CS/CU

7.3±0.20
PEF

25×0.04

32/48/64/80/96/112/128/ 0.12 /0.15 BC/AL/TC

10.3±0.20

75Ω±5

1.83 single
2.77 dual

</DIV>


<DIV align=center> </DIV>

sheave - 绞缆轮,皮带轮,三角皮带轮 (0) 投诉

P:2007-07-31 12:15:35

7

RG type coaxial cable (UL Style 1354)
Standard:U.S.A.MIL-C-ITD

<DIV align=center>

型号 Model

No. of wire/O. D. (mm)

O. D. of insulation (mm)

Al foil

shield n/(mm)

O. D. of jacket (mm)

Characteristic impedance (Ω)

RG-5/U

1/1.29

4.7±0.20

17*0.04

32/48/64/80/96/112/0.12 BC/AL/TC

8.4±0.20

51.5

RG-6/U

1/1.0

4.8±0.20

17x0.04

32/48/64/80/96/112/0.12 BC/AL/TC

7.0±0.20

75.0

RG-6/U

1/1.02

4.7±0.20

17x0.04

32/48/64/80/96/112/0.12 BC/AL/TC

8.4±0.20

76.0

RG-6/UR

7/0.5

4.8±0.20

17x0.04

32/48/64/80/96/112/0.12 BC/AL/TC

7.0±0.20

50.0

RG-6A/U

1/0.724

4.7±0.20

17x0.04

32/48/64/80/96/112/0.12 BC/AL/TC

8.4±0.20

75.0

RG-7/U

1/0.914

7.0±0.20

25x0.04

32/48/64/80/96/112/0.12 BC/AL/TC

9.4±0.20

75.0

RG-8/U

7/0.724

7.2±0.20

25x0.04

32/48/64/80/96/112/0.12 BC/AL/TC

10.3±0.20

50.0

RG-10/U

7/0.724

7.2±0.20

25x0.04

32/48/64/80/96/112/0.12 BC/AL/TC

12.0±0.20

52.0

RG-11/U

7/0.4

7.2±0.20

25x0.04

32/48/64/80/96/112/0.12 BC/AL/TC

10.3±0.20

75.0

RG-12/U

7/0.4

7.2±0.20

25x0.04

32/48/64/80/96/112/0.12 BC/AL/TC

12.0±0.20

75.0

RG-13/U

7/0.4

7.1±0.20

25x0.04

32/48/64/80/96/112/0.12 BC/AL/TC

10.6±0.20

74.0

RG-14/U

1/2.59

9.9±0.20

34 x0.04

32/48/64/80/96/112/0.12 BC/AL/TC

13.8±0.20

52.0

</DIV>


<DIV align=center> </DIV>

bronze conductor - 青铜导线 (0) 投诉

P:2007-08-16 10:35:01

8

楼上的又没有全部的RG线缆的型号啊?

fixed wiring method - 固定布线法 (0) 投诉

P:2007-08-16 20:54:41

9

谢谢哦,这是宝贵的资料了

cold weld - 冷焊 (0) 投诉

P:2007-08-18 02:31:57

10

上我们公司网站,进入RG系列,全部都有!

www.--kingsignal.com

COF - cut-off frequency截止频率 (0) 投诉

P:2007-08-18 17:06:58

11

0

non-conductive waterblocking tape - 非导电挡水带 (0) 投诉

P:2007-09-08 18:08:16

12

真的又长知识了,谢谢了!

hot-melt adhesive material - 热熔胶(电缆外护套连接用) (0) 投诉

P:2007-11-23 21:37:15

13

真的又长知识了,谢谢了!

utraviolet cured silicone acrylamide - 紫外光固化有机硅丙烯酸酯 (0) 投诉

P:2008-03-15 16:54:04

14

   这份资料真是好,我找了好久都没有找到这么好的,关键是不需要钱,好人啊

BX cable - 软电缆,安装用软电缆 (0) 投诉

P:2008-03-28 20:21:09

15

谢谢,我原来做铁路信号的 现在改做同轴啦,多谢大家的资料啊

cotton braiding - 棉纱编织层 (0) 投诉

31