UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 1 Page 10368 Issued: 1998-09-01
Revised: 2003-03-31
Style 10368 XLPE Insulated Wire.
______________________________________________________________________________
Rating 105°C, 300 V.
______________________________________________________________________________
Conductor No. 40-10 AWG, solid or stranded, silver plated, tinned
or bare copper.
______________________________________________________________________________
*Insulation Irradiated PE, 9 mils minimum average thickness, 8 mils
minimum at any point. ______________________________________________________________________________
Standard Appliance Wiring Material UL 758.
______________________________________________________________________________
Instructions Detailed Examination.
*to UL Tensile Strength and Elongation of Insulation
*Representative Spark Test.
______________________________________________________________________________
UL (4) Detailed Examination.
Counter-Check (4) Tensile Strength and Elongation of Insulation.
Program (4) Heat Shock.
(4) Deformation.
(4) Cold Bend.
(12) Horizontal Flame Test.
______________________________________________________________________________
Marking General.
______________________________________________________________________________
Use Internal Wiring of Appliances. Tag may indicate the following: 600 Volts Peak - For Electronic Use Only.