首页 > 国外线缆

[问题求助] 1631电子线的有关知识

P:2007-07-17 14:03:28

1

有哪位大侠知道一些有关1631电子线方面的东东啊?如使用的原材料,技术标准,生产流程,检测方法等等的,谢谢了!

[limingxing 在 2007-10-9 14:37:55 编辑过]

Design Center - 设计中心 (0) 投诉

P:2007-07-20 13:29:12

2

怎么又没的人理哦!!!

soldering seam - 焊缝 (0) 投诉

P:2007-07-20 19:38:25

3

可以自己查阅UL758活页以及UL1581。

high-speed knitting machine - 高速编织机 (0) 投诉

P:2007-08-06 13:51:56

4

UNDERWRITERS LABORATORIES INC.             APPLIANCE WIRING MATERIAL

Subj. 758      Section 1     Page 1631       Issued:  1981-05-20

                                     Revised:  2003-02-26

 

Style 1631    Polyethylene Insulated - Coaxial Cable.

______________________________________________________________________________

 

Rating     60 or 80°C, 30 V.

______________________________________________________________________________

 

Conductor     40 AWG minimum, material not specified.

______________________________________________________________________________

 

Insulation    Solid or Cellular Polyethylene, 3 mils minimum at any point,          100 mils maximum.  May be irradiated.

______________________________________________________________________________

 

Shield     Optional.

______________________________________________________________________________

 

Inner Covering    Optional - Extruded PVC, polyamide, TPE, FEP, PVDF, ETFE,              Irradiated P.E., or FRPE or lacquered braids, 2 mils min. at          any point.

______________________________________________________________________________

 

Outer Conductor   Optional.

______________________________________________________________________________

 

Outer Covering    Optional over braided metal shield, otherwise, Extruded PVC,

           polyamide, FEP, PVDF, ETFE or Lacquered braid, 2 mils min,            at any point. 

______________________________________________________________________________

 

Standard      Appliance Wiring Material UL 758.

______________________________________________________________________________

 

Instructions  Detailed Examination.

to UL

Representative

______________________________________________________________________________

 

UL         (4)  Detailed Examination.

*Counter-Check    (12) Horizontal Flame Test.

Program

______________________________________________________________________________

 

Marking       General.

______________________________________________________________________________

 

Use        Internal Wiring of Electronic Equipment in Class 2 Circuits           only.

 