电线电缆网 > 国外线缆 > UL3135还可以做10AWG和8AWG?(完整版)

UL3135还可以做10AWG和8AWG? - 无图版

newren --- 2011-11-18 11:51:18

1

UL不是规定UL3135是26~12AWG导体吗?<div>
</div><div>
</div><div>请问有什么UL型号的硅胶线可以做到8AWG的?</div>
Killer009 --- 2011-11-18 13:52:32

2

查看UL PAGE页啊<div>
</div>
zhengliang --- 2011-11-19 10:12:05

3

UNDERWRITERS LABORATORIES, INC.                      APPLIANCE WIRING MATERIAL

Subj. 758              Section 3           Page 3135          Issued:  12-19-60

                                                            Revised:  10-16-79

 

 

Style 3135          Silicone Rubber-Insulated Wire.

_______________________________________________________________________________________________

 

Rating              200°C, 600 Volts.

_______________________________________________________________________________________________

 

*Conductor          No. 26-12 AWG solid or stranded of nickel or copper.  All

                    copper shall be tin, nickel or silver coated.  If tinned

                    copper strands are used they shall be 0.0152 inches in

                    diameter or larger, page 26.

_______________________________________________________________________________________________

 

*Insulation         Silicone Rubber, Class 22, 30 mils minimum Average,

                    27 mils minimum at any point.

_______________________________________________________________________________________________

 

Covering            None

_______________________________________________________________________________________________

 

Standard            Flexible Cord and Fixture Wire

_______________________________________________________________________________________________

 

Instructions        Same as for Type SF-2 fixture wire but omit Insulation

to UL                  Resistance Test and vertical flame test.

Representative      Spark Test, Page 30.

                    Flame Test, Page 31.

_______________________________________________________________________________________________

 

UL Counter-Check    (4) Same as for Type SF-2 fixture wire; aging shall be

Program                 conducted annually, omit vertical flame test.

                    (4) Flame Test, Page 31.

_______________________________________________________________________________________________

 

Marking             General, Page 13.

                    Temperature marker required, Pages 19, 20.

                    Items 7a, 7b, 7i, 9k.

_______________________________________________________________________________________________

 

Use                 Internal Wiring of Appliances where totally enclosed.

 

-- 结束 --