电线电缆网 > 国外线缆 > AWM 20798谁有规格书(完整版)

AWM 20798谁有规格书 - 无图版

harahu --- 2011-11-10 11:50:13

1

跪求規格書!
chicheng --- 2011-11-10 12:40:43

2

UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIALS
Subject 758 Section 2 Page 20798 Issued: June 24, 1993
Revised: Nov. 11, 1993
Style 20798 Insulated Flat Cable
________________________________________________________________
Rating 80°C, 60 V
________________________________________________________________
Conductor 2-50, copper foil. Straight parallel in one plane.
Conductors 1.0 - 10.0 mils thick, 10-100 mils wide.
________________________________________________________________
Insulation 0.4 mil min biaxially oriented PETP (polyester)
film bonded each side with 0.5 mil polyester
* adhesive. Min. 13 mils of insulation between
the outside edges and the first conductor and
7 mils minimum width between adjacent conductors.
________________________________________________________________
Shield (Optional) Metal faced polyester tape. Drain
wire optional.
________________________________________________________________
Covering (Optional) Polyester (Mylar) film, 0.02 - 4.0 mils
bonded to cable with polyester adhesive.
________________________________________________________________
Standard Flexible Cord and Fixture Wire (UL 62) and
Test Reference Standard (UL 1581).
________________________________________________________________
Instructions Detailed examination
to UL Flexing - flatwise into a U-bend around
Representative a 1/8 in dia mandrel.
________________________________________________________________
UL (4) Detailed examination
Counter-Check (4) Flexing - Conditioned 7 days in air oven at
Program 113°C, then flexed as above.
(2) Flame Test, Page 31
________________________________________________________________
Marking General, Page 13
________________________________________________________________
Use Internal wiring of Class 2 circuits in electronic
equipment.
-- 结束 --