UNDERWRITERS LABORATORIES | APPLIANCE WIRING MATERIAL |
Subj.758 | Section 3 | Page 3321 | Issued:1977-05-25 |
Revised:2008-05-27 |
Style 3321 | Insulated Wire |
Rating | 150 deg C, 600 Vac, 750 Vdc, Horizontal flame. |
Conductor | 30 AWG - 4/0 AWG solid or stranded round, tinned or bare copper. |
Insulation | XLPE |
30-9 AWG conductor size | 30 mils min average | 27 mils minimum at any point |
8-4 AWG | 45 avg | 40 min |
2 AWG | 60 avg | 54 min |
1-4/0 AWG | 80 avg | 72 min |
Covering | Optional-treated or untreated braid. |
Standard | Appliance Wiring Material UL 758. |
Marking | General. |
Use | Internal wiring of appliances. |
只说2遍 --- 2011-03-24 16:41:32
3
jacksdu --- 2011-04-01 10:50:05
4
a0811bin --- 2011-04-05 22:03:00
5
UNDERWRITERS LABORATORIES, INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 3 Page 3321 Issued: May 25, 1977
Revised: April 10, 2001
*Style 3321 Irradiated or Cross-Linked Polyolefin Insulated Wire.
______________________________________________________________________________
Rating 150°C, 600 V ac, 750 V dc.
______________________________________________________________________________
Conductor Nos.
stranded copper.
______________________________________________________________________________
Insulation Min Average
Conductor Insulation Thickness,
AWG in
_________ _____________________
30 - 9 0.030
8 - 4 0.045
2 0.060
1 - 4/0 0.080
* Thermosetting, Irradiated or cross-linked Polyolefin,
suitable for use at 150°C in air. See facing page for
compound designation.
______________________________________________________________________________
Covering Optional - treated or untreated braid
______________________________________________________________________________
Standard Appliance Wiring Material UL 758.
______________________________________________________________________________
Instructions Detailed Examination.
to UL Tensile strength and elongation of insulation unaged.
*Representative See Facing Page, if not specified, Class 43.
Spark Test
30 - 24 AWG 4,000 V
22 - 20 AWG 5,000 V
19 - 9 AWG 6,000 V
8 - 2 AWG 10,000 V
1 - 4/0 AWG 12,500 V
______________________________________________________________________________
(Continued on Page 3321A)
UNDERWRITERS LABORATORIES, INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 3 Page 3321A Issued: May 25, 1977
Revised: April 10, 2001
UL (4) Detailed Examination.
Counter-Check (4) Tensile strength and elongation, see Facing Page,
*Program if not specified. (7 days at 180°C) Class 43.
(4) Heat Shock, (at 180°C)
(4) Deformation (at 180°C)
(4) Cold Bend Test
(4) Horizontal Flame Test
______________________________________________________________________________
Marking General.
______________________________________________________________________________
Use Internal Wiring of Appliances