电线电缆网 > 国外线缆 > UL21457、21458、21460、21461、21462材质要求?(完整版)
UL21457、21458、21460、21461、21462材质要求? - 无图版
fd1007 --- 2009-12-07 09:00:20
1
zhengliang --- 2009-12-07 09:09:10
2
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 2 Page 21457 Issued: 2005-09-30
Style 21457 | mPPE-PE Insulated and Jacketed Cable. |
Rating | 80°C, voltage not specified. |
Conductor | 30-16 AWG, solid or stranded. |
Insulation | |
Assembly | Two or more insulated conductors. |
Shield | Optional. |
Covering | |
Shield | Optional. |
Jacket | Modified Polyphenylene Ether-Polyethylene (mPPE-PE), 12 mils minimum average, 9 mils minimum at any point. |
Standard | Appliance Wiring Material, UL 758. |
Instructions to UL Representative | Detailed Examination. Physical Properties, Unaged. Spark Test. |
UL Counter‑Check Program | (4) Detailed Examination. (4) Physical Properties. (4) Deformation. (4) Heat Shock. (4) Cold Bend. (12) Horizontal Flame test. |
Marking | General |
Use | Internal Wiring. |
zhengliang --- 2009-12-07 09:09:45
3
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 2 Page 21458 Issued: 2005-09-30
Style 21458 | mPPE-PE Insulated Flat Ribbon Cable. | |
Rating | 80°C, 300 V. | |
Conductor | 2-100 conductors, 32-16 AWG. Conductors laid parallel in one plane. | |
Insulation | Modified Polyphenylene Ether-Polyethylene (mPPE-PE), 15 mils minimum average, 13 mils minimum at any point, before and after ripping. May have a web with 0.5 in. maximum width between insulated conductors. | |
Standard | Appliance Wiring Material UL 758. | |
Instructions to UL Representative | Detailed Examination. Physical Properties. Spark Test. | |
UL Counter‑Check Program | (4) Detailed Examination. (4) Physical Properties. (4) Deformation. (4) Heat Shock. (4) Cold Bend. (12) Horizontal Flame Test. |
|
Marking | General. |
|
Use | Internal wiring. |
|
zhengliang --- 2009-12-07 09:10:19
4
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 2 Page 21460 Issued: 2005-10-24
Style 21460 | mPPE-PE Insulated and Jacketed Cable. |
Rating | 80°C, 300 V. |
Conductor | 40 AWG – 2000 kcmil, solid or stranded. |
Insulation | |
Assembly | Two or more insulated conductors. |
Shield | Optional. |
Covering | |
Shield | Optional. |
Jacket | Modified Polyphenylene Ether-Polyethylene (mPPE-PE), 11 mils minimum average, 8 mils minimum at any point. |
Standard | Appliance Wiring Material, UL 758. |
Instructions to UL Representative | Detailed Examination. Physical Properties, Unaged. Spark Test. |
UL Counter‑Check Program | (4) Detailed Examination. (4) Physical Properties. (4) Deformation. (4) Heat Shock. (4) Cold Bend. (12) Horizontal Flame test. |
Marking | General |
Use | Internal Wiring. |
zhengliang --- 2009-12-07 09:10:41
5
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 2 Page 21461 Issued: 2005-10-24
Style 21461 | mPPE-PE Insulated and Jacketed Cable. |
Rating | 80°C, 600 V. |
Conductor | 40 AWG – 2000 kcmil, solid or stranded. |
Insulation | |
Assembly | Two or more insulated conductors. |
Shield | Optional. |
Covering | |
Shield | Optional. |
Jacket | Modified Polyphenylene Ether-Polyethylene (mPPE-PE), 11 mils minimum average, 8 mils minimum at any point. |
Standard | Appliance Wiring Material, UL 758. |
Instructions to UL Representative | Detailed Examination. Physical Properties, Unaged. Spark Test. |
UL Counter‑Check Program | (4) Detailed Examination. (4) Physical Properties. (4) Deformation. (4) Heat Shock. (4) Cold Bend. (12) Horizontal Flame test. |
Marking | General |
Use | Internal Wiring. |
zhengliang --- 2009-12-07 09:11:10
6
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 2 Page 21462 Issued: 2005-10-24
Style 21462 | mPPE-PE Insulated and Jacketed Cable. |
Rating | 80°C, 1000 V. |
Conductor | 40 AWG – 2000 kcmil, solid or stranded. |
Insulation | |
Assembly | Two or more insulated conductors. |
Shield | Optional. |
Covering | |
Shield | Optional. |
Jacket | Modified Polyphenylene Ether-Polyethylene (mPPE-PE), 11 mils minimum average, 8 mils minimum at any point. |
Standard | Appliance Wiring Material, UL 758. |
Instructions to UL Representative | Detailed Examination. Physical Properties, Unaged. Spark Test. |
UL Counter‑Check Program | (4) Detailed Examination. (4) Physical Properties. (4) Deformation. (4) Heat Shock. (4) Cold Bend. (12) Horizontal Flame test. |
Marking | General |
Use | Internal Wiring. 以上明确要求用mPPE-PE,要按照标准来,除非你不按标准。。 |
[zhengliang 在 2009-12-7 9:12:34 编辑过]
ms02043109 --- 2009-12-07 09:29:41
7
楼上说得好,按标准要求必须得用mPPE-PE,除非你不按标准就另当别论了,但LZ是打样送UL认证?那肯定非用不可了
fd1007 --- 2009-12-07 09:48:04
8
hnivan --- 2009-12-07 11:28:24
9
请联系我,我可为你解决送样难的问题,13609693685文先生