UNDERWRITERS LABORATORIES INC.               APPLIANCE WIRING MATERIAL

Subject 758        Section 2      Page 2464        Issued:  May 2, 1968

                                                  Revised:  Jan. 8, 2001

 

Style 2464    PVC Jacketed Cable.

______________________________________________________________________________

 

Rating     80, 300 V.

______________________________________________________________________________

 

Insulated     Labeled or complying with manufacturer's AWM Procedure

Conductors    having a minimum rating of 80 and 300 V.

______________________________________________________________________________

 

Assembly      Two or more singles, twisted pairs of groups of twisted            singles twisted together or singles or groups of singles

           may be laid parallel to form flat, oval or round cable. 

           Lay not specified.  Barrier layer and/or fillers optional.          Manufacturer shall maintain a complete description of each               assembly.  May use same or mixed AWG size.

______________________________________________________________________________

 

Covering      (Optional) A 6 mil or heavier PVC covering may be extruded            over the conductor assembly.

______________________________________________________________________________

 

*Shield       Optional.

______________________________________________________________________________

 

Jacket     PVC - Class 43

 

                        THICKNESS OF PVC JACKET (mils)

 

           #Dia. of Cable                  Minimum

           Under Jacket      Minimum       at any

           innches.        Average       oint  

 

           0.700 or less        30          24

           0.701 - 1.000        45          36

           1.001 - 1.500        60          48

           1.501 - 2.500        80          64

           2.501 - 4.000       110          88

           4.001 or larger         140         112

 

           # Major dia if cable is flat or oval.

______________________________________________________________________________

 

*Standard     Appliance Wiring Material UL 758.

______________________________________________________________________________

           (Continued on Page 2464A)


UNDERWRITERS LABORATORIES INC.              APPLIANCE WIRING MATERIAL

Subject 758       Section 2     Page 2464A        Issued:  May 2, 1968

                                   Revised:  Jan. 8, 2001

 

Instructions  Detailed examination of the cable assembly and jacket.

*to UL     Physical Properties of Jacket.

Representative    Dielectric Strength Test, 1500 Volts, (Shielded cable only).                         *

 

           The designation of all Styles of the individual conductors               used making up the cable assembly shall be available, and              the UL Representative tag shall indicate if the Style                 is labeled or not.  If they are not labeled, the                     appropriate Follow-Up Tests shall be conducted.

______________________________________________________________________________

 

UL         (4) Detailed Examination.

*Counter-Check    (4) Physical Properties of Jacket.

*Program      (2)   Heat Shock on jacket.

           (2) Deformation on Jacket, Class 43.

*          (4) Cold Bend on completed cable.

*          (2) Vertical Flame Test on completed cable.

 

           If the insulated styles are not labeled, the appropriate              Follow-Up Tests shall be conducted.

______________________________________________________________________________

 

*Marking      General.

______________________________________________________________________________

 

Use        Internal wiring or external interconnection of electronic             equipment (such as desk-type calculators, dictating               machines, or x-ray equipment).

俊辰 --- 2009-09-23 17:37:38

3

UNDERWRITERS LABORATORIES INC.                  APPLIANCE WIRING MATERIAL

Subject 758       Section 2      Page 2092       Issued:  May 1, 1959

                                Revised:  Dec. 4, 2000

 

Style 2092    Two-Conductor P.E. Insulated and PVC Jacketed Cable.

______________________________________________________________________________

 

Rating     60°C, 300 Volts.

______________________________________________________________________________

 

*Conductors       Two 30-16 AWG solid or stranded, tinned or bare copper.

______________________________________________________________________________

 

Insulation    15 mils min avg., 13 mils min at any point Poly­ethylene or             Flame-Retardant Polyethylene

______________________________________________________________________________

 

Conductor     Two individually insulated wires cabled together.  The

Assembly      length of lay of the twisted wires is not specified.               Fillers may be used in a cable but are not required.  A

           barrier layer, if employed, may be 10 mils of extruded PVC,

           a fibrous wrap serving or braid, paper, nylon, oriented

           polyethylene terephthalate, or a thermoplastic-tape wrap. 

           Such a barrier layer would serve to protect the cable during

           further processing and would be applied immediately over the

           twisted assembly of individual conductors or groups of

           conductors.

______________________________________________________________________________

 

*Shielding    Over one or both conductors.

(Optional)

______________________________________________________________________________

 

Jacket     PVC:  15 mils min avg., 13 mils min at any point Class 11.

______________________________________________________________________________

 

*Standard     Appliance Wiring Material UL 758.

______________________________________________________________________________

 

Instructions  Detailed examination

to UL         Physical Properties:  (unaged) Insulation:

*Representative   PE, FRPE, Jacket.

*          Spark Test, 3000 Volts.

______________________________________________________________________________

           (Continued on Page 2092A)


UNDERWRITERS LABORATORIES INC.                  APPLIANCE WIRING MATERIAL

Subject 758       Section 2      Page 2092A       Issued:  May 1, 1959

                                Revised:  Dec. 4, 2000

 

UL         (4)  Detailed examination.

*Counter-Check    (4)  Physical Properties:  Insulation: PE.

*Program           FRPE, Jacket.

*          (4)  Flexibility.

*          (4)  Cold Bend.

*          (4)  Horizontal Flame Test.

*          (4)  Heat Shock.

*          (4)  Deformation, Jacket, Insulation, except at 100°C.

______________________________________________________________________________

 

*Marking      General.

______________________________________________________________________________

 

Use        Internal Wiring of Electronic Equipment.  Tags may indicate

           the following:  "600 Volts peak for electronic use only."

 

dawn3l --- 2009-09-23 19:08:27

4

UNDERWRITERS LABORATORIES INC.               APPLIANCE WIRING MATERIAL

Subj. 758      Section 2      Page 20945      Issued:  Feb. 14, 1997

                                     Revised:  March 23, 2001

 

Style 20945       Flat cable with laminated PVC jacket.

______________________________________________________________________________

 

Rating     80 deg. C, 300 V.

______________________________________________________________________________

 

Conductor     2-31 40 AWG minimum, material not specified.

______________________________________________________________________________

 

Insulation    Solid or cellular PVC, 13 mils minimum at any point,

           100 mils maximum.  May be irradiated.

______________________________________________________________________________

 

Assembly      Insulated singles laid parallel to form flat cable.

______________________________________________________________________________

 

Shield     Metal faced P.E.T.P. film or conductive thermoplastic (PVC), *        Conductive PVC shield, if used, may form a web between             insulated conductors under the jacket.  Both metal faced

           P.E.T.P. film and extruded conductive PVC shield

           may be used in the same cable.

______________________________________________________________________________

 

Jacket     Two laminated sheets, PVC, 9 mils minimum average, 7 mils             minimum at any point.

______________________________________________________________________________

 

*Standard     Appliance Wiring Material UL 758.

______________________________________________________________________________

 

Instructions  Detailed Examination.

to UL         Physical Properties - Insulated Singles prior

*Representative      to assembly - same as Class 43 PVC;

*             Jacket, Class 43 PVC, if Jacket is separable from shield.

           Flexibility - unaged, shall not crack when flexed

              into a "U" bend around a 1/8 inch mandrel.

*            Spark test on insulated singles prior to assemble.

______________________________________________________________________________

                            (Continued on Page 20945A)


UNDERWRITERS LABORATORIES INC.               APPLIANCE WIRING MATERIAL

Subj. 758      Section 2      Page 20945A      Issued:  Feb. 14, 1997

                                     Revised:  March 23, 2001

 

UL         (4)  Detailed Examination.

Counter-Check (4)  Physical Properties - Insulation (if

*Program            separable from shield); Jacket Class 43

*               PVC (if separable from shield).

           (4)  Flexibility - aged 7 days at 113 deg. C then

                flexed as above.

*          (4)  Horizontal Flame Test.

           (4)  Dielectric - 2000 volts for one minute applied between             conductors (tied together) and shield.

______________________________________________________________________________

 

*Marking      General.

______________________________________________________________________________

 

Use        Internal wiring of electronic equipment.

chicheng --- 2009-09-23 19:54:12

5

UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subject 758 Section 2 Page 2493 Issued: Sept. 12, 1969
Revised: Jan. 11, 2001
Style 2493 Thermoplastic (PVC) - Jacketed Cord.
______________________________________________________________________________
Rating 60°C, Voltage rating not specified.
______________________________________________________________________________
Insulated Nos. 30-16 AWG, labeled or complying with Manufacturer’s
Singles AWM Procedure except that AWM rated 30 volts for use in
Class 2 circuits cannot be used.
______________________________________________________________________________
Assembly Consists of two or more conductors, twisted pairs or groups
of twisted conductors twisted together. The conductors or
groups of conductors may be laid parallel forming a flat,
oval or round cable. The lay of the conductors is not
specified. A barrier layer and/or fillers are optional.
Manufacturer shall maintain a complete description of each
assembly. May use same or mixed AWG size.
______________________________________________________________________________
Covering (Optional) - A 6 mil or heavier PVC covering may be extruded
over the conductor assembly.
______________________________________________________________________________
*Shield Optional.
______________________________________________________________________________
Jacket PVC, Class 43.
THICKNESS OF PVC JACKET
#Dia. of Cable Avg. Thickness Min. Thickness
under Jacket in Mils - At any point
in inches Minimum- in Mils
0.425 or less 45 36
0.426 - 0.700 60 48
0.701 - 1.000 80 64
# - Major dia if cable is flat or oval.
______________________________________________________________________________
*Standard Appliance Wiring Material UL 758.
______________________________________________________________________________
(Continued on Page 2493A)
chicheng --- 2009-09-23 19:54:50

6

UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subject 758 Section 2 Page 2493A Issued: Sept. 12, 1969
Revised: Jan. 11, 2001
Instructions Detailed Examination of the cable assembly and jacket wall.
to UL Tensile Strength and Elongation of the jacket, same as for
*Representative Class 43.
* Dielectric Strength Test, 1500 V, (Shielded cable only).
The designation of all Styles of the individual conductors
used making up the cable assembly shall be available, and
the UL Representative’s tag shall indicate if the Style
is labeled or not. If they are not labeled, the
appropriate Follow-Up Tests shall be conducted.
______________________________________________________________________________
UL (4) Detailed Examination.
Counter Check (4) Tensile Strength and Elongation of Insulation and
*Program Jacket.
* (4) Heat Shock on jacket.
(4) Deformation on jacket, Class 43.
* (4) Cold Bend on completed cable.
* (4) Vertical Flame Test on completed cable.
If the insulated Styles are not labeled, the appropriate
Follow-Up Tests shall be conducted.
______________________________________________________________________________
*Marking General.
______________________________________________________________________________
Use External interconnection of electronic equipment
mardini --- 2009-09-23 19:56:10

7

大家都是热心人呀!
chicheng --- 2009-09-23 19:57:01

8

UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subject 758 Section 2 Page 2598 Issued: Aug. 24, 1972
Revised: Jan. 18, 2001
Style 2598 PVC Jacketed Cord.
______________________________________________________________________________
Rating 60°C, 300 Volts.
______________________________________________________________________________
Insulated Labelled or complying with Manufacturer's AWM
Conductors Procedure having a minimum rating of 60°C, 300 V.
______________________________________________________________________________
Fillers Required if necessary to form a relatively
smooth round core for extrusion of outer jacket.
______________________________________________________________________________
Assembly Consists of two or more conductors, twisted pairs or groups
of twisted conductors twisted together. The conductors or
groups of conductors may be laid parallel forming a flat,
oval or round cable. The lay of the conductors is not
specified. A barrier layer and/or fillers are optional.
Manufacturer shall maintain a complete description of each
assembly. May use same or mixed AWG size.
______________________________________________________________________________
Covering (Optional) - A 6 mil or heavier PVC covering may be extruded
over the conductor assembly.
______________________________________________________________________________
*Shield Optional.
_____________________________________________________________________________
*Jacket PVC, Class 43
THICKNESS OF JACKET
#Dia. of Cable Avg. Thickness Min. Thickness
under Jacket in Mils - At any point
in inches Minimum- in Mils
0.700 or less 30 24
0.701 - 1.000 60 48
1.001 - 1.500 80 64
# - Major dia if cable is flat or oval.
_____________________________________________________________________________
(Continued on Page 2598A)
chicheng --- 2009-09-23 19:57:49

9

UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subject 758 Section 2 Page 2598A Issued: Aug. 24, 1972
Revised: Jan. 18, 2001
*Standard Appliance Wiring Material UL 758.
______________________________________________________________________________
Instructions Detailed Examination of the Cable Assembly and
to UL Jacket Wall. Tensile Strength and Elongation
Representative of the Jacket, Class 43.
* Dielectric Strength Test, 1500 V, (Shielded cable only).
The designation of all Styles of the individual conductors
used making up the cable assembly shall be available, and
the UL Representative's tag shall indicate if the Style is
labelled or not. If they are not labelled, the appropriate
Follow-Up Tests shall be conducted.
______________________________________________________________________________
UL (4) Detailed Examination.
Counter Check (4) Tensile Strength and Elongation of Jacket,
Program Class 43.
* (4) Heat Shock on Jacket.
* (4) Deformation on Jacket.
* (4) Cold Bend on Completed Cable
* (4) Vertical Flame Test on Completed Cable.
If the insulated Styles are not labelled, the
appropriate Follow-Up Tests shall be conducted.
______________________________________________________________________________
*Marking General.
______________________________________________________________________________
Use Internal wiring or external interconnection of electronic
equipment.
chicheng --- 2009-09-23 20:02:34

10

UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subject 758 Section 2 Page 2919 Issued: March 22, 1978
Revised: Feb. 12, 2001
Style 2919 Low Voltage Computer Cable.
Rating 80°C, 30 Volts.
Insulated
Conductors
No. 40 AWG minimum. Labeled or complying with Manufacturer’s
AWM Procedure having a minimum rating of 80°C, 30 V.
Assembly Consists of two or more conductors, twisted pairs or groups
of twisted conductors twisted together. The conductors or
groups of conductors may be laid parallel forming a flat,
oval or round cable. The lay of the conductors is not
specified. A barrier layer and/or fillers are optional.
Manufacturer shall maintain a complete description of each
assembly. May use same or mixed AWG size.
Covering (Optional) - A 6 mil or heavier PVC covering may be extruded
over the conductor assembly.
*Shield Optional.
Jacket PVC - Class 43
THICKNESS (MILS)
#Dia of cable
under jacket Minimum Minimum
in inches Average at any point
_____________ ________ ____________
0.425 or less 30 24
0.426 - 0.700 45 36
0.701 - 1.000 60 48
1.000 - 1.500 80 64
1.501 - 2.500 110 88
2.501 and larger 140 112
# - Major dia if cable is flat or oval.
*Standard Appliance Wiring Material UL 758.
(Continued on Page 2919A)
chicheng --- 2009-09-23 20:02:50

11

UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subject 758 Section 2 Page 2919A Issued: March 22, 1978
Revised: Feb. 12, 2001
Instructions
*to UL
Representative
Detailed Examination.
Tensile Strength and Elongation of Jacket.
The designation of all Styles of the individual conductors
used making up the cable assembly shall be available, and the
UL Representative’s tag shall indicate if the Style is
labeled or not. If they are not labeled, the appropriate
Follow-Up Tests shall be conducted.
UL
Counter-Check
*Program
*
*
*
(4) Detailed Examination.
(4) Tensile Strength and Elongation of Jacket.
(4) Heat Shock on Jacket.
(4) Deformation on Jacket.
(4) Cold Bend on Complete Cable.
(4) Vertical Flame Test on Complete Cable.
If the insulated Styles are not labeled, the appropriate
Follow-Up Tests shall be conducted.
*Marking General.
Use As internal wiring or external interconnection in Class 2
Circuits of electronic computers and electric business
machines.
dgutczb --- 2009-09-24 09:26:29

12

看到满满的UL资料,小弟真正的感觉到论坛的温暖! 小弟在这里向曾经帮助过小弟的各路英雄好汉表示衷心的感谢!

真的觉得自己无以为报!

假如各路英雄有用得着小弟的地方,加我Q 445956848, 小弟将知无不言,言无不尽!

 

谢谢了!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

bsdtdw --- 2009-09-24 15:44:38

13

有关UL 758 型号,去这个网站查就好了。

http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.html

芝麻开门了 --- 2009-09-24 16:00:57

14

授人以鱼,不如授人以渔
-- 结束 --