看UL Style PAGE 中UL Counter-Check Program中有要求
| UNDERWRITERS LABORATORIES | APPLIANCE WIRING MATERIAL | ||||
| Subj.758 | Section 2 | Page 20276 | Issued:1983-08-16 |
| | Revised:2009-01-05 | ||
| Style 20276 | Jacketed Cable | |
| Rating | 60, 80 deg C; 30 V ac; Cable Flame, construction A; Horizontal flame, construction B. |
| Conductor | 40 AWG min., solid or stranded round. May use same or mixed AWG size. |
| Insulation | Labeled or complying with AWM Procedure. |
| Assembly | Consistsof two or more conductors, twisted pairs, parallel pairs, or groups oftwisted conductors or parallel pairs twisted together. The conductorsor groups of conductors may be laid parallel forming a flat, oval orround cable. The lay of the insulated conductors are not specified. Abarrier layer and/or fillers are optional. Manufacturer shall maintaina complete description of each assembly. |
| Shield | Optional. |
| Covering | Optional - A 6 mil or heavier PVC covering may be extruded over the conductor assembly. |
| Jacket | PVC |
| dia of cable under jacket of 0.350 inches or less | (constr A) | 20 mils min average | 17 mils minimum at any point |
| dia of cable under jacket of 0.350 inches or less | (constr B) | 15 avg | 12 min |
| 0.351-0.700 dia | (const A) & (const B) | 30 avg | 24 min |
| 0.701 -1.00 dia | (const A) & (const B) | 40 avg | 36 min |
| 1.001-1.50 dia | (const A) & (const B) | 54 avg | 48 min |
| Standard | Appliance Wiring Material UL 758. |
| Marking | General. |
| Use | ConstructionA: Internal wiring or external interconnection of electronic equipmentin Class 2 circuits only. Construction B: Internal wiring of electronicequipment in Class 2 circuits only. |
[做电线的 在 2009-4-16 14:13:53 编辑过]
复杂的很啊
这个简单啊,直接看UL758标准和UL1581标准知道了呀!
Style PAGE 这个是一个总体的标准,是做线的线材标准,也就是各条线的UL要求.我说的UL758标准和UL1581这两个标准是专讲线材的各项测试要求和讲解怎么测试的.
专家碰上专家,一定会冒火花。
每種線材都須符合一種燃燒要求,如線材上印上VW-1,那就必須符合VW-1燃燒標准(測試項目方法請參照UL758&UL1581),相反的,如果不能符合VW-1燃燒標准,那就不能印,關鍵是看公司或客戶要求線材須符合哪種燃燒要求。
線材進行UL認証時是要進行阻燃檢測授權
现在最新的UL标准都改成不需要过VW-1,只要过水平就好!可以不用那么严格来控制了!
线材印字的燃烧等线要看你当初申请ul认证时所发的ul细则,已明确规定.
現在的 ul style page 真的 讓人無所適從了. 我們今年五月份認證下來的 無鹵部分 比如 20844 21088 21099 21451 這些style page 里面 新版的 沒有要求 flame 等級. 而認證 資料里面 給了一個 vw-1 沒有 授權. rating : vw-1 flame rating not authorzed .
我做印字輪 該怎樣選 flame 等級呢.
</FORM>谁知道UL 3499 绝缘材料有什么要求?
文科生:
<FORM id=koudai_form_article action=http://koudai.360.cn/index.php?c=tool&a=article&title=&url=http%3A%2F%2Fwww.dxdlw.com%2FShowPost.asp%3FPageIndex%3D2%26ThreadID%3D48285&from=tool method=post target=koudai_tool_frame>現在的 ul style page 真的 讓人無所適從了. 我們今年五月份認證下來的 無鹵部分 比如 20844 21088 21099 21451 這些style page 里面 新版的 沒有要求 flame 等級. 而認證 資料里面 給了一個 vw-1 沒有 授權. rating : vw-1 flame rating not authorzed .
我做印字輪 該怎樣選 flame 等級呢.
</FORM>
那就不可以放VW-1了!你的成品只需要測Horinzontal Flame Test
你試試看UL Style Page的 Rating那邊該有沒有燃燒等級
[aou83 在 2009-7-24 13:46:20 编辑过]
做电线的:
具体对应的规范是哪个?下面为我在UL网站上看到的关于AWM20276的一份Stlye PAGE
但是并没有看到要求,所以还是有点迷茫。。。。
UNDERWRITERS LABORATORIES APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20276 Issued:1983-08-16 Revised:2009-01-05
Style 20276 Jacketed Cable
Rating 60, 80 deg C; 30 V ac; Cable Flame, construction A; Horizontal flame, construction B.
Conductor 40 AWG min., solid or stranded round. May use same or mixed AWG size.
Insulation Labeled or complying with AWM Procedure.
Assembly Consistsof two or more conductors, twisted pairs, parallel pairs, or groups oftwisted conductors or parallel pairs twisted together. The conductorsor groups of conductors may be laid parallel forming a flat, oval orround cable. The lay of the insulated conductors are not specified. Abarrier layer and/or fillers are optional. Manufacturer shall maintaina complete description of each assembly.
Shield Optional.
Covering Optional - A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
Jacket PVC
dia of cable under jacket of 0.350 inches or less (constr A) 20 mils min average 17 mils minimum at any point dia of cable under jacket of 0.350 inches or less (constr B) 15 avg 12 min 0.351-0.700 dia (const A) & (const B) 30 avg 24 min 0.701 -1.00 dia (const A) & (const B) 40 avg 36 min 1.001-1.50 dia (const A) & (const B) 54 avg 48 min
Standard Appliance Wiring Material UL 758.
Marking General.
Use ConstructionA: Internal wiring or external interconnection of electronic equipmentin Class 2 circuits only. Construction B: Internal wiring of electronicequipment in Class 2 circuits only.
RATING那邊有指明
在ul758中,你们ul认证时所发的细则有明确的规定,你按照细则上要求即是,
如果没有,它上面也会写vw-1没许可,即不能印vw-1字样,哪只要通过水平测试即可,
FT1 , FT2 是C(UL)即CAS加拿大标准.
学习啦
學習了!
依當初公司所申請的標准來測
VW-1嚴個點

UL20276 style page 变成这样的了...
落后的很....
做电线的:
是的,呵呵,谢谢了,仔细看了下,确实是最基本的要求的测试都在上面了。。。。
还有上面对应的section对应的是1581的么?
还有一个就是比如说20276的那样子的AWM,对绝缘料没有要求的,这个时候应该根据
什么样子的规范或者要求来选择呢[做电线的 在 2009-4-16 14:13:53 编辑过][/blockquot]
对应的就是758里的章节啊 比如 : section 7 就是指第七章
| Style 20276 | Jacketed Cable | |
| Rating | 60, 80 deg C; 30 V ac; Cable Flame, construction A; Horizontal flame, construction B. Cable Flame, construction A;对于A结构类型,为电缆阻燃,B结构为为水平阻燃。 |
无卤阻燃TPU/TPE先行者 欢迎致电:13929267115 徐先生
学习了
hezhi03052:ul 20276必须达到:FT1燃烧等级