请教各位材料的专家,标准UL 1581上规定UL 60度的

护套料老化后抗张强度的保留率为:大于等于85% 

断裂伸长率的保留率为:大于等于45%

没有具体说明护套材料老化前和老化后的变化率为多少?请问各位大侠UL护套材料有没有这个变化率的要求。

绿茶 --- 2008-11-24 13:17:33

2

护套材料老化前和老化后的变化率就为你上表所写的数据呀!

alan79114 --- 2008-11-28 22:10:17

3

按照UL444第四版的标准,条款7.8.2所述,UL CM等级60C的护套应该在 100 ±2°C老化7天后,只要拉伸达到未老化前的50%,扩张达到未老化前的75%,就是合格的,而不是依据UL1581来判定。

7.8.2 For cables to be rated 60°C, jacket material removed from a length of finished cable shall meet the
aging test as follows. After 7 d, at 100 ±2°C, there shall be at least 50% retention of the unaged elongation
and 75% retention of unaged tensile strength when six specimens are tested in accordance with the test
procedures in CSA C22.2 No. 2556 or UL 2556, with the following modifications: