电线电缆网 > 国外线缆 > UL1061 和UL1007有什麽區別啊(完整版)
UL1061 和UL1007有什麽區別啊 - 无图版
LL725 --- 2008-07-19 08:47:18
1
电线菜鸟 --- 2008-07-19 10:02:07
2
相同条件下的 绝缘厚度 完成外径 容许电流有不同!
相同点是都是电子线系列!
另1061多用于制作芯线!
cuijiude --- 2008-07-19 10:11:55
3
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 1 Page 1061 Issued: 1959-05-01
Revised: 2004-02-17
Style 1061 | Semi-Rigid PVC or SRPVC Insulated Wire. |
Rating | 80°C, 300 Volts. |
Conductor | No. 30-16 AWG, solid or stranded. |
Insulation | Semi-Rigid PVC: 9 mil average, 7 mil minimum at any point. |
Standard | Appliance Wiring Material UL 758. |
Instructions to UL Representative | Detailed Examination. Physical Properties, Unaged. Spark Test. |
UL Counter-Check Program * | (4) Detailed Examination. (4) Physical Properties. (4) Heat Shock. (4) Cold Bend. (4) Deformation. (12) Horizontal Flame Test. |
Marking | General. |
Use | Internal Wiring in Electric Bookkeeping, Accounting, Time-Recording Machines, or Electronic Equipment if within a chassis or protected from mechanical injury. |
cuijiude --- 2008-07-19 10:12:39
4
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 1 Page 1007 Issued: 1959-05-01
Revised: 2002-12-05
Style 1007 Polyvinyl Chloride Insulated Wire.
______________________________________________________________________________
Rating 80°C, 300 V.
______________________________________________________________________________
Conductor 32-16 AWG, solid or stranded.
______________________________________________________________________________
Insulation Polyvinyl Chloride, 15 mils minimum average,
13 mils minimum at any point, 60 or 80°C in oil,
if applicable.
______________________________________________________________________________
Standard Appliance Wiring Material UL 758.
______________________________________________________________________________
Instructions Detailed Examination.
to UL Physical Properties, Unaged.
Representative Spark Test.
______________________________________________________________________________
UL (4) Detailed Examination.
Counter-Check (4) Physical Properties.
Program (4) Heat Shock.
(4) Cold Bend
* (4) Deformation.
* (12) Horizontal Flame Test.
______________________________________________________________________________
Marking General.
______________________________________________________________________________
Use Internal wiring of appliances; or where exposed to oil
at a temperature not exceeding 60°C or 80°C, whichever
is applicable. Tags may indicate the following:
600 V Peak - For Electronic Use Only.
阿卜 --- 2008-07-19 20:09:38
5
zsl1128 --- 2008-07-21 22:06:43
6
zym2009 --- 2009-10-31 13:48:13
7