UL标准绝缘跟护套平均厚度怎么算的,没变跟国标算法有什么不同么?
| APPLIANCE WIRING MATERIAL | ![]() | ||||
| Subj.758 | Section 1 | Page 1007 | Issued:1959-05-01 |
| Revised:2013-02-22 | |||
| Style 1007 | Single Conductor with Extruded Insulation | |
| Rating | 80 deg C, 300 Vac, Horizontal flame. Optional - 60 deg C or 80 deg C Oil. | |||||||||
| Conductor | 32 AWG - 16 AWG, Solid or Stranded. | |||||||||
| Insulation | Extruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point. | |||||||||
| Standard | Appliance Wiring Material UL 758. | |||||||||
| Marking | General. | |||||||||
| Use | Internal wiring of appliances. Tags may indicate the following: 600 V Peak - For Electronic Use Only. | |||||||||
平均厚度是通过UL标准设定的乘以0.0254吧、那他的最小厚度呢?是用他的平均厚度乘以0.9减去0.1么?关键就是他的最小厚度让人搞不懂,好像是绝缘层的最小厚度跟护套层的不一样吧?
哦哦哦 懂了懂了 谢谢大神解答
你好 谢谢您愿意解答 我已经弄清楚了 再次感谢
1223042850:来这里,我来教你算
帮忙看下此款线材3266#20 平均绝缘厚度是多少?公式如何计算的?
1223042850:413258050:来这里,我来教你算
帮忙看下此款线材3266#20 平均绝缘厚度是多少?公式如何计算的?
15mils是平均厚度 13mils是任意点的最小厚度 按平均厚度15mils做线材 但最薄不能小于13mils 否则就是不符合UL规范了
絕緣材料,交聯PE,絕緣平均厚度0.381mm,最薄點不得小於0.33mm.