电线电缆网 > 国外线缆 > 请问有USB2.0 线的资料吗?参照UL哪个标准做的?(完整版)

请问有USB2.0 线的资料吗?参照UL哪个标准做的? - 无图版

溺水的鱼 --- 2006-09-26 09:10:02

1

谢谢!
River --- 2006-09-26 09:31:31

2

你的制作依據是USB協會規范。可以參照UL2725、2835、20276等

hust --- 2006-09-27 08:51:04

3

0USB2.0测试规格.pdfUSB2.0测试标准
heqiongyuan --- 2006-09-27 11:27:10

4

我那有个USB2.0的行业标准,不知是否对你有帮助

heqiongyuan --- 2006-09-27 11:51:00

5

文件太大,上传不了,郁闷
roger --- 2006-11-08 11:10:05

6

有MICRO-USB资料吗?
秋波儿 --- 2006-12-18 10:55:36

7

看不到

kyle --- 2007-01-05 10:36:37

8

大家好.

请问有谁知道USB协会的联系方式?

roger --- 2007-01-05 16:46:06

9

直接上USB协会网站www.usb.org ,国内如果要搞USB认证直接找台湾ETC,我去年刚搞过
seawolfjia --- 2007-10-16 16:52:58

10

USB2.0的电线结构和传输特性的标准是在USB2.0规范上的,但在USB2.0的规范上并没有规定符合那个安规,一般情况下我们是依UL规范做的,因为USB2,0的结构按UL758标准对号入座的话有2725,20276,20379等等很多,有的厂家还用2835,所以这个并没有定论,要看你客户的要求了.
manwang801 --- 2007-11-11 12:07:57

11

look



orange --- 2007-11-26 12:23:20

12

就是2樓回答的

will99999 --- 2007-11-30 15:52:27

13

USB2.0 的標準是要求TYPE CM(UL444) 的。 協會認証好象也接受2725。
manwangwei --- 2008-04-28 12:56:08

14

UNDERWRITERS LABORATORIES INC.              APPLIANCE WIRING MATERIAL

Subj. 758     Section 2     Page 2725        Issued:  1975-05-02

                                Revised:  2003-04-04

 

Style 2725    Electronic Cable.

______________________________________________________________________________

 

Rating     60°C or 80°C, 30 V.

______________________________________________________________________________

 

Insulated     Labeled or Complies with manufacturer's AWM Procedure.

Singles       May include mixed sizes.

______________________________________________________________________________

 

Conductor     Two, three, or four parallel, or two or more Assembly

           twisted insulated singles or groups of twisted singles

           twisted together or groups of twisted singles may be laid

           parallel to form flat or oval cable.  Lay not specified

           barrier layer and/or fillers optional.  Manufacturer shall

           maintain a complete description of each assembly.  Diameter

           of assembly under jacket one inch maximum.

______________________________________________________________________________

 

Shield     Optional.

______________________________________________________________________________

 

Jacket     PVC, Class 43, 9 mils minimum average, 7 mils minimum at

           any point.

______________________________________________________________________________

 

Standard      Appliance Wiring Material UL 758.

______________________________________________________________________________

 

Instructions  Detailed Examination.

to UL

Representative

______________________________________________________________________________

 

UL         (4)  Detailed Examination.

Counter-Check (4)  Flexing.

*Program      (12) Horizontal Flame Test.

______________________________________________________________________________

 

Marking       General.

______________________________________________________________________________

 

Use        Internal wiring of electronic equipment in Class 2 systems

           only.

manwangwei --- 2008-04-28 12:57:10

15

UNDERWRITERS LABORATORIES INC.                     APPLIANCE WIRING MATERIAL

Subj. 758        Section 2        Page 2835        Issued:  1976-10-28

                                                  Revised:  2003-01-03

 

Style 2835

 

PVC Jacketed Cable.

 

Rating

 

 

60°C, 30 V.

 

Conductor

 

 

40 AWG minimum.  Material not specified.

 

Insulated

Singles

 

 

Material not specified for use statement 1A or 1B.  Labeled or complies with manufacturer's Procedure for use statement 2A or 2B.

 

 

Assembly

 

 

Consists of two or more conductors, twisted pairs, or groups of twisted conductors.  The conductors may be laid parallel or twisted together to form a flat, oval, or round cable construction.  Lay not specified.  Barrier layer and/or fillers optional. May use same or mixed AWG sizes.  Manufacturer shall maintain a complete description of each assembly.

 

 

Covering

 

 

Optional.  PVC, 5 mils minimum at any point, over the assembly or groups of singles.

 

 

Shield

 

Optional.  May be over one or more of the  insulated conductors or applied over the assembly.

 

 

Jacket

 

 

 

 

 

 

 

 

*

*

 

 

PVC - Class 43.

 

If parallel construction is rippable, the measurements are made after ripping.

 

  Dia# of Cable

  under Jacket               Minimum        Minimum

   in inches              Average (mils)  at any point

 

0.250 or less (1A,2A only)      15             13

0.250 or less (1B,2B only)      30             27

0.251 - 0.424                   30             27

0.425 - 0.700                   60             48

0.701 - 1.500                   80             64

1.501 - 2.500                  110             88

2.501 or larger                140            112

 

# = Major diameter if flat or oval construction.

 

                            (Continued on Page 2835A)

 

 


UNDERWRITERS LABORATORIES INC.                      APPLIANCE WIRING MATERIAL

Subj. 758        Section 2        Page 2835A        Issued:  1976-10-28

                                                   Revised:  2003-01-03

 

 

Standard

 

 

Appliance Wiring Material UL 758.

 

Instructions

to UL

Representative

 

 

Detailed Examination.

 

UL

Counter-Check

Program

 

 

(4)  Detailed Examination.

(4)  Flexibility Test.

(12) Cable Flame Test on Completed Cable, External Use,

     Constructions 1B and 2B.

(12) Horizontal Flame Test on Completed Cable Internal

     Use, Constructions 1A and 2A.

 

 

Marking

 

 

General.

 

 

Use No. 1A

 

 

Use No. 1B

 

 

 

 

Use No. 2A

 

 

 

Use No. 2B

 

Internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors.

          

CABLES - using 30 mils or greater jacket thickness only:  External interconnection or internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors.

 

Internal wiring in Class 2 circuits of electronic equipment where not routed along walls, floors, or other abuse areas.

          

CABLES - using 30 mils or greater jacket thickness only:  External interconnection or internal wiring in Class 2.

 

 

 

发财 --- 2008-07-29 19:38:23

16

USB2.0的行业标准

哪位高手有中文的?

loveyjwu --- 2008-08-16 09:59:45

17

虽隔半年,但现在有这方面的资料提供参考,我积极参与!



loveyjwu --- 2008-08-16 10:02:57

18

虽隔半年,但现在有这方面的资料提供参考,我积极参与!



kyle0755 --- 2008-11-04 15:46:52

19

我有USB2.0标准,英文版本的,谁要???

kyle.chen0755@163.com

 

zym2009 --- 2009-10-27 15:03:11

20

USB2.0的行业标准
he528xn --- 2010-01-20 21:30:45

21

usb一般都按2725要求做
zhengliang --- 2010-01-30 16:06:52

22

River:

你的制作依據是USB協會規范。可以參照UL2725、2835、20276等

补充一个:2547也可以

海天一色 --- 2010-02-10 16:44:50

23

有USB协会认证的,就可以印USB字样;

没有认证的,多以2725的印字出现。

gufengyiye --- 2011-11-06 22:48:53

24

学习了

-- 结束 --